Chile Concepción Industrial Workshop Lighting Upgrade Project

150W LED Flood Light Industrial Lighting Upgrade for Manufacturing Workshop

Project Type: Industrial Workshop Lighting Upgrade
Location: Concepción, Chile
Application: Industrial Workshops
Product: LED Flood Lights
Supplier: LIKELITE
Project Quantity: 1,000 Sets


Project Overview

The Chile Concepción Industrial Workshop Lighting Upgrade Project was developed to improve lighting performance, reduce energy consumption, and create a safer working environment for industrial operations.

The existing workshop lighting system required improvement in:

  • Lighting efficiency
  • Workplace visibility
  • Energy management
  • Maintenance cost control

LIKELITE provided a complete industrial LED lighting upgrade solution, including lighting design, engineering calculation, product supply, and installation support.

The final solution applied 150W LED Flood Lights with intelligent control systems to optimize lighting performance and achieve approximately 22% energy saving.


Project Background

Industrial Workshop Lighting Requirements

Industrial workshops require reliable lighting systems to support:

  • Manufacturing operations
  • Equipment inspection
  • Worker safety
  • Production efficiency
  • Continuous operation

The project required lighting equipment capable of providing:

  • High brightness output
  • Stable illumination
  • Long operating lifespan
  • Industrial protection
  • Lower energy consumption

Project Challenges

1. Large Workshop Lighting Coverage

The industrial workshop required a lighting system capable of covering large working areas with consistent illumination.

The lighting design needed to consider:

  • Workshop layout
  • Installation positions
  • Lighting distribution
  • Working zones

2. Energy Consumption Optimization

The previous lighting system resulted in unnecessary energy consumption during periods with limited human activity.

The project required an intelligent lighting management system to reduce operating costs.


3. Industrial Environment Requirements

The lighting fixtures needed to withstand:

  • Dust conditions
  • Temperature changes
  • Long operating hours

The selected products required:

  • IP protection
  • Surge protection
  • Reliable thermal management

Project Solution

LIKELITE 150W LED Flood Light System

LIKELITE supplied:

1,000 sets of 150W LED Flood Lights

with intelligent lighting control technology.


Product Configuration

ItemSpecification
Product NameLED Flood Lights
Power150W
Quantity1,000 Sets
CertificationSEC
Warranty2 Years
Energy Saving22%
BrandLIKELITE
OriginGuangdong, China

Technical Specifications

ParameterDetails
Input VoltageAC100-240V
LED SourceCREE SMD2835 LED
Efficiency140 lm/W
Beam Angle120°
IP RatingIP65
MaterialALU + PC
Lamp Body MaterialAluminum Alloy
Surge Protection10KV
Voltage Resistance1.5KV
CCT5000K ±300K
CRIRa80
Lifespan30,000 Hours
Frequency50HZ
Working Temperature-20℃ ~45℃
Power SupplyAC

Intelligent Lighting Control System

Microwave Motion Sensor + Light Control + Timer Control

To maximize energy efficiency, LIKELITE integrated an intelligent control system.


Microwave Motion Sensor

The sensor automatically detects activity within the workshop area.

Benefits:

  • Reduces unnecessary lighting operation
  • Improves energy efficiency
  • Supports automated lighting management

Light Control System

The system adjusts lighting operation according to surrounding brightness conditions.

Benefits:

  • Optimized electricity usage
  • Improved operational efficiency

Timer Control System

The timer function allows customized lighting schedules.

Benefits:

  • Flexible operation management
  • Reduced unnecessary energy consumption

Engineering Design Services

LIKELITE provided complete engineering support:

Lighting And Circuitry Design

Including:

  • Lighting system planning
  • Electrical compatibility analysis
  • Installation recommendations

Onsite Metering

Engineering evaluation included:

  • Existing illumination measurement
  • Site condition assessment
  • Installation environment analysis

Lighting Simulation

Professional simulation services:

DIALux Evo Layout

Used for:

  • Lux calculation
  • Lighting distribution analysis
  • Uniformity evaluation

LitePro DLX Layout

Used for:

  • LED performance comparison
  • Lighting optimization

AutoCAD Layout

Used for:

  • Installation drawings
  • Construction reference

AGI32 Layout

Used for:

  • Advanced lighting simulation
  • Engineering verification

Project Implementation

Engineering Process

Step 1: Site Evaluation

LIKELITE engineers analyzed:

  • Workshop structure
  • Existing lighting condition
  • Electrical system

Step 2: Lighting Design

The engineering team completed:

  • Lighting layout
  • Simulation calculation
  • Product configuration

Step 3: Product Manufacturing

Production included:

  • LED performance inspection
  • Electrical testing
  • Quality control

Step 4: Delivery and Installation Support

LIKELITE provided:

  • Technical documents
  • Installation guidance
  • Project support

Project Results

Improved Industrial Lighting Performance

After installation of the LIKELITE LED Flood Light system:

Energy Saving

Achieved approximately:

22% Energy Consumption Reduction


Improved Lighting Reliability

The upgraded system provided:

✓ Higher lighting efficiency
✓ Better workplace visibility
✓ Reduced maintenance requirements
✓ Intelligent lighting management

Before & After Comparison



DIALux EVO Lighting Simulation Verification


Project Value

The Chile Concepción Industrial Workshop Lighting Upgrade demonstrates LIKELITE's capability in delivering Industrial Lighting Projects for international markets.

The project combined:

  • Professional engineering design
  • High-efficiency LED technology
  • Smart control systems
  • Reliable manufacturing
  • Overseas project support

Why Industrial Customers Choose LIKELITE

Professional Project Experience

LIKELITE supports:

  • Industrial facility owners
  • EPC contractors
  • Engineering companies
  • Lighting distributors

Complete Project Capability

From:

Requirement Analysis

Lighting Design

Simulation Calculation

Production

Delivery

Installation Support

LIKELITE provides complete industrial lighting project execution capability.


Industrial Lighting Project FAQ

1. What type of project was the Chile Concepción lighting upgrade?

It was an industrial workshop lighting upgrade project using LED Flood Lights to improve efficiency and lighting performance.


2. How many LED Flood Lights were installed?

The project included 1,000 sets of 150W LED Flood Lights.


3. What energy savings were achieved?

The upgraded lighting system achieved approximately 22% energy saving.


4. What LED technology was used?

The project used CREE SMD2835 LED technology with 140 lm/W efficiency.


5. Did the project include intelligent controls?

Yes. The system included microwave motion sensor, light control, and timer control.


6. What certification was provided?

The project products were supplied with SEC certification requirements for Chile.


7. What lighting simulation software was used?

LIKELITE provided DIALux Evo, LitePro DLX, AutoCAD, and AGI32 layouts.


8. What is the lifespan of the LED Flood Lights?

The designed lifespan is up to 30,000 hours.


9. Can LIKELITE provide industrial lighting design services?

Yes. LIKELITE provides onsite measurement, lighting calculation, and engineering design support.


10. What warranty was provided?

The project included a 2-year warranty.


11. Can LIKELITE supply large Industrial Lighting Projects?

Yes. LIKELITE supports bulk project supply for international industrial facilities.


12. Where are LIKELITE lighting products manufactured?

LIKELITE LED lighting products are manufactured in Guangdong, China.


Project Contact

Looking for Industrial LED Lighting Project Solutions?

LIKELITE provides professional industrial lighting project services for factories, workshops, warehouses, EPC contractors, and engineering companies.

Contact LIKELITE for:

  • Industrial lighting design
  • Project quotation
  • DIALux simulation
  • Bulk LED lighting supply