Genoa Outdoor Sports Facility Lighting Modernization Project

High-Efficiency LED Stadium Lighting Upgrade for Sports Facilities in Genoa, Italy

Project Location: Genoa, Italy
Project Type: Sports Facility Lighting Upgrade
Application: Outdoor Sports Venue
Product: LED Stadium Lights
Quantity: 400 Sets
Power: 200W
Energy Saving: 20%
Certification: CE / RoHS / ENEC
Warranty: 2 Years
Supplier: LIKELITE
Origin: Guangdong, China


Project Overview

LIKELITE supplied high-performance LED stadium lighting systems for an outdoor sports facility lighting modernization project in Genoa, Italy.

The project focused on upgrading existing outdoor sports lighting infrastructure with advanced LED Stadium Lights to improve illumination quality, enhance visual performance and reduce long-term energy consumption.

A total of:

400 sets of 200W LED Stadium Lights

were supplied for the sports facility upgrade.

The upgraded lighting system achieved:

20% Energy Saving

through:

  • High-efficiency LED technology

  • Optimized beam distribution

  • Improved lighting performance

  • Intelligent dimming capability

LIKELITE provided complete engineering support including:

  • Lighting and Circuitry Design

  • Onsite Metering

  • DIALux Evo Layout

  • LitePro DLX Layout

  • AutoCAD Layout

  • AGi32 Layout

  • Project Installation Support


Project Information

Project ItemDetails
LocationGenoa, Italy
Project TypeStadium Lighting Upgrade
ApplicationOutdoor Sports Facility
ProductLED Stadium Lights
Quantity400 Sets
Power200W
Energy Saving20%
CertificationCE / RoHS / ENEC
Warranty2 Years
SupplierLIKELITE

Sports Lighting Upgrade Requirements

Outdoor sports facilities require reliable lighting systems that provide clear visibility, uniform illumination and stable operation during sporting activities.

The Genoa project required:

  • Improved nighttime sports visibility

  • High brightness illumination

  • Better visual comfort

  • Reduced energy consumption

  • Long service life

  • Reliable outdoor performance

The selected LED stadium lighting system provides an efficient upgrade solution for outdoor sports venues.


Engineering Design & Project Services

LIKELITE provided a complete sports lighting engineering process.

Lighting and Circuitry Design

The lighting system was designed according to sports venue requirements and installation conditions.

Onsite Metering

Site measurements supported accurate lighting planning.

DIALux Evo Layout

Professional simulation was completed to evaluate illumination performance.

LitePro DLX Layout

Additional engineering layouts supported project coordination.

AutoCAD Layout

Technical drawings supported installation preparation.

AGi32 Layout

Lighting calculations verified system performance.

Project Installation Support

LIKELITE provided installation coordination during project execution.


LED Stadium Lighting Performance

The project adopted:

OSRAM SMD3030 LED Technology

Main specifications:

  • Power: 200W

  • LED Source: OSRAM SMD3030

  • Luminous Efficiency: 160 lm/W

  • Beam Angle: 120°

  • Color Temperature: 5000K ±500K

  • Color Rendering Index: Ra70

  • Input Voltage: 195V-265V AC

  • Frequency: 50Hz

  • Power Factor: 0.95

The lighting system provides high brightness and stable illumination for outdoor sports applications.


High-Performance Sports Lighting Features

The LED stadium lights were designed with:

High Brightness Output

The 160 lm/W luminous efficiency provides powerful illumination for outdoor sports facilities.

Lightweight Structure

The optimized aluminum structure helps simplify installation and maintenance.

Dimming Support

The system supports dimming functions for flexible lighting management.

Professional Optical Distribution

The 120° beam angle provides wide-area illumination coverage.


Outdoor Protection & Reliability

Sports lighting equipment must operate under changing outdoor conditions.

The project specification included:

  • IP66 protection rating

  • IK09 impact resistance

  • 4KV surge protection

  • Die-casting aluminum ADC12 housing

  • PC lens + glass structure

  • Operating temperature: -35°C to +45°C

The design ensures reliable operation in outdoor sports environments.


Energy Saving Results

The Genoa Outdoor Sports Facility Lighting Upgrade achieved:

20% Energy Saving

The improvement was achieved through:

  • 160 lm/W LED efficiency

  • Optimized lighting distribution

  • Dimming support

  • Reduced energy consumption

The upgrade helps the sports facility achieve better lighting performance with improved operational efficiency.


Product Technical Specification

ParameterSpecification
ProductLED Stadium Lights
BrandLIKELITE
Power200W
Input Voltage195V-265V AC
LED SourceOSRAM SMD3030
Luminous Efficiency160 lm/W
Beam Angle120°
CCT5000K ±500K
CRIRa70
IP RatingIP66
IK RatingIK09
Surge Protection4KV
MaterialAluminum
Housing MaterialDie-casting Aluminum ADC12
Lens MaterialPC Lens + Glass
Lifespan30,000 Hours
Frequency50Hz
PF0.95
Working Temperature-35°C to +45°C
CertificationCE / RoHS / ENEC
Warranty2 Years

Project Implementation Process

LIKELITE followed a professional stadium lighting workflow:

Site Assessment → Lighting Design → Simulation Verification → Product Supply → Installation Support

This engineering process ensures the lighting system meets sports facility requirements.


 

Before & After Comparison



DIALux EVO Lighting Simulation Verification


Project Results

The Genoa Outdoor Sports Facility Lighting Modernization Project demonstrates LIKELITE's capability in international sports lighting projects.

Project achievements:

  • 400 sets LED Stadium Lights supplied

  • 200W high-efficiency LED system

  • 20% energy saving improvement

  • Professional sports lighting design

  • Reliable outdoor performance

  • Engineering installation support

The project represents:

Sports Lighting Engineering + LED Technology + Optical Performance + Project Delivery


Project Value

This project provides reference experience for:

  • Sports venues

  • Stadium contractors

  • Municipal sports facilities

  • EPC companies

  • Lighting engineering consultants

LIKELITE supports global stadium lighting projects through:

  • Lighting design

  • Simulation services

  • LED stadium lighting supply

  • Project implementation support


Stadium Lighting Project FAQs

1. Where was this stadium lighting project located?
The project was located in Genoa, Italy.

2. What type of project was completed?
An outdoor sports facility lighting upgrade project.

3. How many LED stadium lights were supplied?
400 sets.

4. What was the power rating?
200W LED Stadium Lights.

5. What energy saving was achieved?
Approximately 20%.

6. What certifications were provided?
CE, RoHS and ENEC certifications.

7. What LED technology was used?
OSRAM SMD3030 LED.

8. What was the luminous efficiency?
160 lm/W.

9. What protection rating was provided?
IP66 and IK09.

10. Does the system support dimming?
Yes.

11. Did LIKELITE provide lighting simulation?
Yes, including DIALux Evo and AGi32.

12. What is the lifespan of the LED stadium lights?
30,000 hours.

13. What is the operating temperature range?
-35°C to +45°C.

14. Did LIKELITE provide installation support?
Yes.

15. Can LIKELITE support international stadium lighting projects?
Yes, LIKELITE supports sports lighting projects worldwide.


Project Inquiry

Planning an outdoor sports lighting upgrade?

LIKELITE provides:

Sports Lighting Design → Simulation → LED Stadium Light Supply → Installation Support

Project: Genoa Outdoor Sports Facility Lighting Upgrade
Location: Italy
Product: LED Stadium Lights
Quantity: 400 Sets
Power: 200W
Energy Saving: 20%