High-Bay & Workshop Lighting | LED Flood Lights | Smart Lighting Control | Lighting Engineering
Industrial workshops require lighting systems that provide sufficient illumination for production areas, equipment zones, storage areas, maintenance areas and circulation spaces while maintaining reliable operation under demanding working conditions.
LIKELITE provides Industrial LED Lighting Solutions combining:
LED Flood Lights + Lighting Design + Onsite Metering + Lighting Simulation + Smart Control + Project Installation
For industrial retrofit applications, the lighting system is configured according to the actual building structure, mounting conditions, working environment, existing lighting system and required operating schedule.
A representative industrial application in Tijuana, Mexico used 150W LED Flood Lights with 130 lm/W luminous efficiency, IP65 protection and smart lighting control.
The reported energy-saving improvement for that application was:
27%
Industrial Lighting Solution Overview
| Solution Item | Configuration |
|---|---|
| Application | Industrial Workshops |
| Reference Market | Tijuana, Mexico |
| Product | LED Flood Lights |
| Rated Power | 150W |
| Quantity Reference | 2,000 sets |
| Reported Energy-Saving Improvement | 27% |
| Smart Control | Microwave Motion Sensor + Light Control + Timer Control |
| Input Voltage | AC127V |
| Frequency | 60Hz |
| LED Source | CREE SMD3030 |
| Luminous Efficiency | 130 lm/W |
| IP Rating | IP65 |
| Beam Angle | 120° |
| Surge Protection | 10KV |
| Voltage Resistance | 1.5KV |
| CCT | 5000K ±400K |
| CRI | Ra 80 |
| Housing | Aluminum Alloy |
| Material | ALU + PC |
| Lifespan | 30,000 Hours |
| Working Temperature | -20°C to +45°C |
| Certification | NOM |
| Warranty | 2 Years |
| Power Supply | AC |
| Origin | Guangdong, China |
| Brand | LIKELITE |
Industrial Lighting Challenges
Industrial workshops are different from standard commercial spaces.
The lighting system may need to operate around:
Production equipment
Machinery
Workstations
Storage areas
Loading and unloading zones
Maintenance areas
Internal circulation areas
High ceilings
Dust and environmental exposure
Long operating hours
A suitable industrial lighting system therefore requires more than simply replacing existing lamps with higher-efficiency LED fixtures.
The lighting layout, mounting position, beam distribution, operating schedule and control strategy should be considered together.
LIKELITE Industrial Lighting Approach
1. Existing Lighting Assessment
Before replacing the existing fixtures, LIKELITE can review the current lighting system and collect project information.
Typical information includes:
Existing luminaire wattage
Existing luminaire quantity
Mounting height
Fixture spacing
Workshop dimensions
Production area layout
Working zones
Operating hours
Existing lighting control
Power supply
Environmental conditions
This information provides the basis for the proposed LED lighting configuration.
2. Onsite Metering
For retrofit projects, onsite metering can be used to understand existing lighting conditions.
Measurements may be used to evaluate:
Existing illumination
Lighting distribution
Dark areas
High-traffic areas
Working zones
Existing lighting uniformity
The final measurement scope depends on the project requirements.
Industrial Lighting Design
Lighting and Circuitry Design
LIKELITE provides lighting and circuitry design support for industrial applications.
The design considers:
Building Structure → Working Areas → Fixture Position → Optical Distribution → Electrical Configuration → Control Strategy
The objective is to establish a practical lighting system rather than simply maximize luminaire output.
DIALux Lighting Simulation
Industrial Lighting Projects can be evaluated using professional lighting simulation tools.
LIKELITE supports:
DIALux Evo Layout
LitePro DLX Layout
AutoCAD Layout
AGi32 Layout
The simulation process can be used to evaluate the proposed fixture arrangement before installation.
Depending on the project requirements, the design can evaluate:
Illuminance
Lighting distribution
Uniformity
Fixture arrangement
Mounting configuration
Working-area lighting
Actual calculation results depend on the building dimensions, mounting height, fixture spacing, photometric data and project requirements.
Industrial LED Flood Lights
150W LED Flood Lights
The reference industrial application uses:
150W
LED Flood Lights.
The configuration provides:
130 lm/W
specified luminous efficiency.
Optical Configuration
Light Source: CREE SMD3030
Beam Angle: 120°
Color Temperature: 5000K ±400K
CRI: Ra 80
Electrical Configuration
Input Voltage: AC127V
Frequency: 60Hz
Power Supply: AC
Surge: 10KV
Voltage Resistance: 1.5KV
Mechanical Configuration
IP Rating: IP65
Material: ALU + PC
Lamp Body: Aluminum Alloy
Working Temperature: -20°C to +45°C
Lifespan: 30,000 Hours
Smart Industrial Lighting Control
Industrial facilities often have different operating periods and occupancy conditions.
LIKELITE can integrate:
Microwave Motion Sensor
Used to detect movement within the configured area and support demand-based lighting operation.
Light Control
Used to control lighting according to ambient lighting conditions.
Timer Control
Used to establish defined operating schedules.
The reference configuration combines:
Microwave Motion Sensor + Light Control + Timer Control
The actual control logic should be configured according to the industrial facility's operating requirements.
Energy-Saving Strategy
Energy efficiency in an industrial lighting retrofit depends on both the LED fixture and the way the lighting system operates.
The reference Tijuana industrial application reported:
27% Energy-Saving Improvement
The result should be evaluated against the original lighting system and actual operating conditions.
Factors affecting energy consumption include:
Existing fixture wattage
LED replacement wattage
Number of fixtures
Daily operating hours
Working shifts
Occupancy
Motion-control settings
Timer settings
Ambient lighting conditions
For this reason, the 27% figure is a project-specific reference result and not a universal guaranteed saving rate.
Industrial Lighting Applications
LIKELITE Industrial Lighting Solutions can be configured for:
Manufacturing Workshops
Lighting for production lines, machinery and workstations.
Industrial Workshops
General lighting for workshop environments.
Warehouse Areas
Lighting for storage, handling and internal circulation.
Maintenance Areas
Lighting for equipment inspection and maintenance work.
Loading Areas
Lighting for loading, unloading and material movement.
Industrial Buildings
General-purpose lighting for industrial facilities.
Production Facilities
Lighting systems for manufacturing and processing environments.
Engineering Service
LIKELITE can provide an engineering-oriented service workflow:
Site Information
↓
Onsite Metering
↓
Lighting & Circuitry Design
↓
DIALux / AGi32 / LitePro DLX / AutoCAD
↓
Fixture Selection
↓
Smart Control Configuration
↓
Technical Confirmation
↓
Production
↓
Quality Inspection
↓
Delivery
↓
Project Installation
This workflow allows the lighting equipment to be configured around the actual facility instead of treating the luminaire as an isolated product.
Industrial Lighting System Configuration
A typical industrial lighting system can include:
LED Flood Lights
Lighting Layout
Electrical Design
Smart Control
Lighting Simulation
Installation Support
The final system configuration depends on:
Facility structure
Ceiling height
Working plane
Production requirements
Fixture position
Existing electrical system
Operating schedule
Environmental conditions
Why Choose LIKELITE for Industrial Lighting?
Project-Based Configuration
Lighting equipment is selected according to the application rather than using one standard configuration for every facility.
Engineering Support
Lighting and circuitry design, onsite metering and professional lighting layout support can be provided.
Simulation Support
DIALux Evo, LitePro DLX, AutoCAD and AGi32 layout services are available according to project requirements.
Smart Control
Microwave motion sensing, light control and timer control can be combined for industrial applications.
Bulk Supply
The reference application involved 2,000 sets of LED Flood Lights.
International Project Support
LIKELITE supplies outdoor and industrial LED lighting products from Guangdong, China for overseas projects.
Product Compliance
The reference industrial lighting configuration includes:
NOM
The product configuration was specified with NOM certification for the Mexican market application.
Certification requirements should always be confirmed against the final product configuration and applicable local regulations.
Warranty
The reference product configuration includes:
2-Year Warranty
Warranty conditions are subject to the final commercial agreement and product warranty terms.
Packaging Information
Reference product packaging:
Single Package Size: 21 × 11 × 8 cm
Single Gross Weight: 9.15 kg
The packaging data can support:
Shipping calculation
Warehouse planning
Container loading
Project logistics
Site delivery planning
Industrial Lighting Solution Selection
For a new industrial lighting project, LIKELITE recommends confirming the following information before final configuration:
Facility Information
Building dimensions, ceiling height and internal layout.
Lighting Requirements
Target illumination, working-plane requirements and operating conditions.
Existing System
Current fixture wattage, quantity and operating schedule.
Electrical Conditions
Input voltage, frequency and existing circuitry.
Control Requirements
Motion sensing, daylight control, timer operation or other control requirements.
Project Quantity
Estimated fixture quantity and installation schedule.
This information allows the proposed LED lighting system to be evaluated before procurement.
Industrial Lighting Solutions FAQ
1. What type of facilities are suitable for LIKELITE Industrial Lighting Solutions?
The solutions can be configured for industrial workshops, manufacturing facilities, warehouses, maintenance areas, loading areas and other industrial buildings.
2. What LED Flood Light wattage is used in the Tijuana reference application?
The reference configuration uses 150W LED Flood Lights.
3. How many fixtures were included in the reference application?
The reference quantity was 2,000 sets.
4. What was the reported energy-saving improvement?
The reported result was 27%.
5. What LED source was used?
The reference configuration uses CREE SMD3030 LED.
6. What is the specified luminous efficiency?
The specified luminous efficiency is 130 lm/W.
7. What input voltage is available for the reference configuration?
The configuration uses AC127V, 60Hz.
8. Can LIKELITE provide DIALux calculations for industrial facilities?
Yes. DIALux Evo, LitePro DLX, AutoCAD and AGi32 layout support can be provided according to project requirements.
9. Can smart controls be integrated into industrial lighting?
Yes. Microwave motion sensor, light control and timer control can be integrated according to the facility's operating requirements.
10. Is the LED Flood Light suitable for demanding industrial environments?
The reference fixture is configured with IP65 protection and an operating temperature range of -20°C to +45°C. Suitability should be confirmed against the actual industrial environment.
11. What surge protection is specified?
The reference configuration includes 10KV surge protection.
12. What certification is specified for the Mexico application?
The reference configuration specifies NOM.
13. What is the warranty period?
The reference configuration includes a 2-year warranty.
14. What information is needed for an industrial lighting design?
Typical information includes building dimensions, ceiling height, fixture mounting positions, existing lighting data, operating hours, electrical conditions and required lighting levels.
15. Can LIKELITE support large industrial lighting orders?
Yes. The Tijuana reference application involved 2,000 sets, and LIKELITE can provide bulk supply according to confirmed project specifications.
Request an Industrial Lighting Proposal
Planning an industrial workshop retrofit, manufacturing facility lighting upgrade or warehouse lighting project?
Send LIKELITE:
Facility Drawings + Ceiling Height + Existing Lighting Data + Operating Hours + Electrical Information + Lighting Requirements + Estimated Quantity
LIKELITE can provide:
LED Flood Lights + Industrial Lighting Design + DIALux Simulation + Smart Control + Technical Documentation + Bulk Supply + Installation Support
LIKELITE
Industrial LED Lighting Solutions for Workshops, Manufacturing Facilities and Industrial Buildings.