LIKELITE supplied 2,000 sets of 80W LED Roadway Lights for an urban roadway lighting upgrade project in Jeddah, Saudi Arabia.
The project specification required SASO certification, AC 220V operation, IP65 outdoor protection and 10KV surge protection, with a specified luminous efficiency of 120 lm/W and a 2-year warranty.
The project was developed to upgrade the existing roadway lighting system while improving lighting efficiency and reducing operating energy consumption.
LIKELITE's project scope included roadway lighting product supply together with:
Lighting and Circuitry Design + Onsite Metering + DIALux Evo Layout + LitePro Dlx Layout + AutoCAD Layout + AGi32 Layout + Project Installation Support
Project Overview
Jeddah Urban Roadway Lighting Upgrade
Project Item
Project Specification
Project Location
Jeddah, Saudi Arabia
Project Type
Urban Roadway Lighting Upgrade
Application
City / Municipal Roadway
Product
LED Roadway Lights
Rated Power
80W
Quantity
2,000 sets
Certification
SASO
Input Voltage
AC 220V
Frequency
60Hz
IP Rating
IP65
LED Source
CREE SMD2835
Luminous Efficiency
120 lm/W
Beam Angle
120°
CCT
5000K ±500K
CRI
Ra 80
Surge Protection
10KV
Voltage Resistance
1.5KV
Housing
Aluminum Alloy
Material
ALU + PC
Lifespan
30,000 hours
Power Supply
AC
Working Temperature
-20°C to +45°C
Warranty
2 years
Energy Saving
20% project target
Origin
Guangdong, China
Brand
LIKELITE
Project Scope
LED Replacement for Urban Roadway Lighting
The Jeddah project focused on upgrading roadway lighting through the deployment of 80W LED Roadway Lights.
The project scope covered:
Existing roadway lighting assessment
Onsite metering
Lighting and circuitry design
LED roadway luminaire configuration
Photometric layout
Electrical layout
Installation coordination
Project installation support
The engineering work was coordinated around the project's electrical supply, roadway conditions, luminaire configuration and required outdoor protection.
Project Requirement
From Existing Roadway Lighting to LED
The project required a roadway lighting configuration suitable for an urban outdoor environment with:
AC 220V electrical supply
60Hz operating frequency
SASO certification requirement
IP65 protection
10KV surge protection
120 lm/W specified luminous efficiency
5000K ±500K color temperature
2-year warranty
The selected 80W LED roadway luminaire was configured around these project requirements.
Selected Product
80W LED Roadway Lights
The project used an 80W LED Roadway Light equipped with a CREE SMD2835 LED light source.
The specified luminous efficiency is:
120 lm/W
The luminaire uses a 120° beam angle for broad roadway light distribution.
The final lighting performance depends on roadway width, mounting height, pole spacing, installation angle and project-specific photometric calculations.
Technical Configuration
Optical Parameters
Parameter
Specification
LED Source
CREE SMD2835
Luminous Efficiency
120 lm/W
Beam Angle
120°
Color Temperature
5000K ±500K
Color Rendering Index
Ra 80
Rated Power
80W
Electrical Configuration
AC 220V / 60Hz Roadway Lighting
The Jeddah project uses an AC electrical configuration:
Input Voltage: AC 220V
Frequency: 60Hz
The luminaire also includes:
10KV surge protection
1.5KV voltage resistance
AC power supply
The electrical parameters were specified according to the project requirements.
Outdoor Protection
IP65 Aluminum Alloy Housing
The LED roadway luminaire uses:
IP65 protection + Aluminum Alloy housing
The IP65 enclosure provides protection against dust ingress and water jets for outdoor roadway applications.
The aluminum alloy lamp body provides mechanical protection and supports heat dissipation during continuous operation.
The specified operating temperature is:
-20°C to +45°C
For Projects with operating conditions outside this range, LIKELITE can review the required product configuration separately.
Project Engineering Services
From Site Data to Installation
The Jeddah project included engineering services supporting the roadway lighting upgrade.
Onsite Metering
Existing site information can be collected to establish the technical basis for the replacement lighting system.
Lighting and Circuitry Design
Roadway lighting and electrical layouts can be developed according to the project requirements.
DIALux Evo Layout
DIALux Evo can be used for roadway lighting simulation and photometric analysis.
LitePro Dlx Layout
LitePro Dlx layout support is available for Projects using this design platform.
AGi32 Layout
AGi32 can be used for photometric calculation and roadway lighting analysis.
AutoCAD Layout
AutoCAD drawings can be used for engineering coordination and installation documentation.
Project Installation
Installation-related technical support can be provided according to the project scope.
Project Implementation
Typical Installation Sequence
The Jeddah roadway lighting upgrade follows a project-oriented installation process.
01 — Existing Lighting Review
Review the existing roadway lighting equipment, poles, electrical connections and site conditions.
02 — Site Measurement
Collect roadway dimensions, pole spacing, mounting height and existing lighting information.
03 — Lighting Layout
Develop the proposed LED roadway lighting layout using the required design software.
04 — Product Confirmation
Confirm the 80W luminaire configuration, electrical parameters, optical distribution and protection requirements.
05 — Product Supply
Manufacture and supply the approved LED roadway lighting configuration.
06 — Installation
Install the LED roadway luminaires according to the approved project requirements.
07 — Commissioning
Inspect the completed installation and make required installation adjustments.
Project Quantity
2,000 Sets of LED Roadway Lights
The project quantity was:
2,000 sets
With each luminaire rated at 80W, the nominal connected load of the supplied luminaires is:
160 kW
This figure represents the nominal LED fixture load based on:
2,000 × 80W = 160,000W
Actual system consumption depends on driver characteristics, operating conditions and control equipment.
Energy Saving Performance
20% Energy Saving Target
The project specification indicates an energy-saving improvement of:
20%
The actual energy-saving result of a roadway lighting retrofit depends on the comparison between the existing system and the new LED system.
Relevant factors include:
Existing luminaire wattage
Existing ballast losses
New LED connected load
Daily operating hours
Annual operating hours
Lighting control strategy
Existing and proposed lighting levels
Therefore, the 20% figure is presented as the project-specified energy-saving target, unless measured energy data is available.
If the project owner provides utility records or measured connected-load data, LIKELITE can support a before-and-after energy comparison.
Project Performance Highlights
Key Project Data
2,000 Sets
LED roadway luminaires supplied
80W
Rated power per luminaire
120 lm/W
Specified luminous efficiency
120°
Beam angle
IP65
Outdoor protection
10KV
Surge protection
SASO
Specified certification
AC 220V / 60Hz
Electrical configuration
2 Years
Warranty
20%
Specified energy-saving target
Project Value
What the Jeddah Project Demonstrates
The Jeddah project demonstrates LIKELITE's ability to support a project-scale urban roadway lighting upgrade with both product and engineering services.
The project combines:
2,000-set LED supply + 80W roadway luminaires + SASO specification + AC220V + photometric design support + installation support
For EPC contractors and municipal infrastructure buyers, the project provides a reference for evaluating LIKELITE's capability to handle bulk roadway lighting requirements together with technical design coordination.
Before & After Comparison
DIALux EVO Lighting Simulation Verification
Why This Project Is Relevant to Roadway Lighting Buyers
A Project Reference for Municipal and EPC Procurement
Roadway lighting buyers typically need more than a product catalogue.
They need to understand:
Project scale
Product configuration
Electrical compatibility
Certification
Outdoor protection
Engineering support
Installation capability
Warranty
Energy performance
The Jeddah project brings these procurement factors together in one project reference.
For additional engineering methodology and general roadway lighting capabilities, buyers can refer to the separate Roadway Lighting Solutions page.
Similar Roadway Lighting Project Support
For Municipalities, EPC Contractors and Engineering Companies
LIKELITE can support similar roadway lighting Projects based on:
Project location
Roadway dimensions
Pole height
Pole spacing
Existing luminaire type
Existing wattage
Electrical voltage
Required certification
Lighting standard
Quantity
Installation requirements
CAD drawings
Site photographs
The final product configuration should be determined from project-specific technical requirements rather than copied directly from the Jeddah reference.
Request a Similar Project Proposal
Send LIKELITE your project information for technical evaluation.
Recommended information includes:
Project Location Roadway Width Pole Height Pole Spacing Existing Lighting Type Existing Wattage Quantity Input Voltage Required Certification Lighting Standard CAD Drawings Site Photos
LIKELITE can then prepare a proposed LED roadway lighting configuration, photometric layout and commercial quotation.
LIKELITE — LED Roadway Lighting for Municipal and Infrastructure Projects
Jeddah Roadway Lighting Project FAQ
1. Where is the project located?
The project is an urban roadway lighting upgrade reference for Jeddah, Saudi Arabia.
2. How many LED roadway lights are included?
The project specification includes 2,000 sets.
3. What wattage is used?
The specified LED roadway luminaire is 80W.
4. What certification is specified?
The project configuration specifies SASO certification.
5. What is the input voltage?
The specified input voltage is AC 220V.
6. What is the operating frequency?
The specified frequency is 60Hz.
7. What LED source is used?
The specified luminaire uses CREE SMD2835 LED.
8. What is the luminous efficiency?
The specified luminous efficiency is 120 lm/W.
9. What is the IP rating?
The specified protection rating is IP65.
10. What surge protection is included?
The luminaire is specified with 10KV surge protection.
11. What color temperature is used?
The specified color temperature is 5000K ±500K, with CRI Ra 80.
12. What is the warranty period?
The specified warranty period is 2 years.
13. What energy saving is specified?
The project specification indicates an energy-saving target of 20%. Actual energy savings depend on the existing lighting system, operating hours, LED load and control strategy.
14. What engineering services were included?
The specified service scope includes Lighting and Circuitry Design, Onsite Metering, DIALux Evo Layout, LitePro Dlx Layout, AutoCAD Layout, AGi32 Layout and Project Installation.
15. Can LIKELITE supply similar roadway lighting projects?
Yes. LIKELITE can develop project-specific roadway lighting configurations for municipalities, EPC contractors, engineering companies and infrastructure buyers according to local electrical, certification, environmental and lighting requirements.