Industrial workshops require lighting systems that provide adequate visibility for production, maintenance, material handling and inspection while controlling energy consumption and operating costs.
LIKELITE provides industrial LED lighting solutions combining LED Flood Lights, lighting design, onsite measurement, lighting simulation, electrical planning and smart lighting control.
The solution can be configured for:
Industrial workshops
Manufacturing facilities
Production plants
Warehouses
Assembly areas
Maintenance workshops
Machinery areas
Industrial storage areas
High-ceiling industrial spaces
Retrofit lighting projects
Industrial Lighting Solution at a Glance
| Item | Solution Configuration |
|---|---|
| Main Product | LED Flood Lights |
| Reference Power | 200W |
| LED Source | CREE SMD3030 |
| Luminous Efficiency | 135 lm/W |
| Beam Angle | 120° |
| Input Voltage | AC90–305V |
| IP Rating | IP65 |
| Smart Control | Microwave Motion Sensor + Light Control + Timer Control |
| Surge Protection | 10KV |
| Voltage Resistance | 1.5KV |
| CCT | 5000K ±400K |
| CRI | Ra80 |
| Lifespan | 30,000 hours |
| Working Temperature | -20°C to +45°C |
| Power Supply | AC |
| Frequency | 47–63Hz |
| Engineering Services | Lighting Design, Onsite Metering, DIALux Evo, LitePro DLX, AutoCAD, AGi32, Installation |
Industrial Lighting Engineering Requirements
Industrial lighting design must be based on the actual working environment rather than simply replacing an existing lamp with a lower-wattage LED fixture.
The engineering assessment normally considers:
Production Area
Different production processes require different lighting levels, distribution and visual conditions.
Machinery and Equipment
Large machinery, structural elements, pipes, beams and equipment can create shadows and obstruct light distribution.
Mounting Height
The mounting height directly affects beam coverage, illumination level and luminaire spacing.
Workstation Arrangement
Lighting should correspond to the actual working areas, inspection points and production layout.
Operating Schedule
Industrial facilities may operate during daytime, night shifts or multiple shifts, making operating control important for energy management.
Existing Lighting System
Existing fixture wattage, quantity, installation position and operating schedule should be evaluated before determining the replacement configuration.
LIKELITE Industrial Lighting Solution Methodology
01 — Existing Lighting Assessment
The first stage is to establish the existing lighting condition.
Typical information includes:
Existing luminaire type
Existing wattage
Luminaire quantity
Mounting height
Installation spacing
Workshop dimensions
Working area
Existing illumination
Operating hours
Electrical supply
Control method
This information provides the basis for replacement planning.
02 — Onsite Metering
Where required, LIKELITE can support onsite measurement before the final lighting configuration is selected.
Typical measurements include:
Workshop length and width
Ceiling or mounting height
Luminaire positions
Working-plane height
Existing illumination
Equipment layout
Production zones
Electrical conditions
The objective is to build the lighting design around the actual facility.
03 — Industrial Lighting Design
The lighting layout should be developed according to:
Workshop dimensions
Mounting height
Luminaire spacing
Working-plane height
Production arrangement
Required illumination
Uniformity requirements
Maintenance access
Electrical layout
The final number and wattage of luminaires should be determined by project-specific calculation rather than by wattage substitution alone.
200W LED Flood Light Configuration
A 200W LED Flood Light can be used as a reference configuration for industrial workshop lighting applications.
LED Technology
CREE SMD3030 LED
Luminous Efficiency
135 lm/W
Beam Angle
120°
Color Temperature
5000K ±400K
Color Rendering Index
Ra80
The configuration provides a practical starting point for industrial areas requiring broad light distribution.
The actual luminaire quantity, spacing, mounting angle and wattage should be confirmed through project-specific lighting calculations.
DIALux Evo Industrial Lighting Simulation
Lighting simulation is an important part of an industrial lighting project where the workshop geometry and equipment layout need to be evaluated before installation.
LIKELITE can provide:
DIALux Evo Layout
The simulation can evaluate:
Illuminance
Uniformity
Luminaire arrangement
Mounting height
Beam distribution
Working-plane illumination
Lighting coverage
Potential shadow areas
LitePro DLX / AutoCAD / AGi32
Industrial Lighting Projects may require different engineering documentation depending on the project team.
LitePro DLX
For lighting layout and optical evaluation.
AutoCAD
For:
Lighting layouts
Luminaire positioning
Electrical drawings
Circuit planning
Engineering documentation
AGi32
For additional lighting calculation and engineering verification where required.
These tools form part of the engineering workflow rather than being presented as standalone marketing features.
Smart Industrial Lighting Control
Industrial facilities often have different operating periods, working zones and occupancy levels.
LIKELITE can configure:
Microwave Motion Sensor + Light Control + Timer Control
Microwave Motion Sensor
Motion detection can be used to respond to activity within designated areas.
This can be useful for:
Low-occupancy zones
Storage areas
Auxiliary areas
Maintenance areas
Intermittently used workshop sections
Light Control
Light-control functions can respond to ambient daylight conditions.
This can help avoid unnecessary lighting operation where sufficient natural light is available.
Timer Control
Timer control allows lighting schedules to be configured according to operating requirements.
The three functions can be combined according to the facility's operating pattern.
Industrial Energy-Saving Strategy
Industrial lighting energy consumption is influenced by more than fixture wattage.
The main variables include:
Connected Load + Operating Hours + Lighting Control + Existing System Efficiency
For retrofit projects, LIKELITE can evaluate the relationship between the existing lighting system and the proposed LED system.
The reference configuration uses:
200W LED Flood Lights + Smart Control
A reported reference project achieved a:
25% Energy-Saving Improvement
This figure belongs to the specific reference project and should not be treated as a universal saving guarantee.
Actual energy savings depend on:
Existing fixture wattage
Existing lighting efficiency
Operating hours
Number of fixtures
Control strategy
Production schedule
Required lighting level
Outdoor / Industrial Protection
Industrial lighting equipment may be exposed to dust, moisture, temperature variation and mechanical operating conditions.
The reference configuration includes:
IP65
Protection against dust ingress and water jets from applicable directions.
10KV Surge Protection
Designed to provide additional protection against electrical surge conditions.
1.5KV Voltage Resistance
Specified as part of the electrical protection configuration.
Aluminum Alloy Housing
The lamp body uses aluminum alloy with an ALU + PC material configuration.
Industrial Lighting Engineering Services
LIKELITE can support Industrial Lighting Projects through the following services:
Lighting and Circuitry Design
Development of lighting and electrical layouts according to facility requirements.
Onsite Metering
Measurement of existing facility conditions before final configuration.
DIALux Evo Layout
Project-specific lighting simulation.
LitePro DLX Layout
Additional optical and lighting layout support.
AutoCAD Layout
Engineering drawings and luminaire/circuit layouts.
AGi32 Layout
Additional lighting calculation where required.
Project Installation
Installation and commissioning support according to project requirements.
Reference Industrial Lighting Application
Saint-Étienne, France — Industrial Workshop Lighting Upgrade
The Saint-Étienne reference case provides a practical industrial workshop application for the solution configuration.
Application: Industrial Workshops
Product: LED Flood Lights
Power: 200W
Quantity: 1,000 sets
Certification: CE (LVD + EMC) / RoHS / ErP
Warranty: 2 Years
Reported Energy-Saving Improvement: 25%
Smart Control: Microwave Motion Sensor + Light Control + Timer Control
Reference Product Configuration
Input Voltage: AC90–305V
IP Rating: IP65
LED: CREE SMD3030
Beam Angle: 120°
Efficiency: 135 lm/W
Surge Protection: 10KV
Voltage Resistance: 1.5KV
CCT: 5000K ±400K
CRI: Ra80
Lifespan: 30,000 hours
Operating Temperature: -20°C to +45°C
Frequency: 47–63Hz
This reference project demonstrates how the industrial lighting solution can combine LED Flood Lights, smart control and project engineering services.
For detailed project evidence, the dedicated project page should contain the actual project documentation, photographs, calculation reports and installation records where available.
Industrial Lighting FAQ
1. What is an industrial LED lighting solution?
An industrial LED lighting solution combines LED luminaires with lighting design, electrical planning, simulation, control and installation according to the actual requirements of an industrial facility.
2. What type of LED lights are suitable for industrial workshops?
LED Flood Lights can be used for workshops and industrial areas where broad light distribution and higher installed mounting positions are required. Final selection depends on workshop geometry and lighting requirements.
3. Is 200W suitable for industrial workshop lighting?
A 200W LED Flood Light can be used as one configuration for industrial workshop applications. The correct wattage should be verified through project-specific lighting calculations.
4. What LED technology is used in the reference configuration?
The reference configuration uses CREE SMD3030 LED.
5. What is the luminous efficiency of the reference LED Flood Light?
The specified luminous efficiency is 135 lm/W.
6. What beam angle is used?
The reference configuration uses a 120° beam angle.
7. Can LIKELITE provide DIALux lighting calculations?
Yes. LIKELITE can provide DIALux Evo layouts based on verified workshop dimensions, mounting height, luminaire arrangement and project lighting requirements.
8. Can industrial lighting use motion sensors?
Yes. Microwave motion sensors can be integrated into industrial lighting control strategies for suitable areas and operating conditions.
9. Can timer and light control be combined with motion sensing?
Yes. The reference configuration combines Microwave Motion Sensor + Light Control + Timer Control.
10. What is the IP rating of the reference industrial LED Flood Light?
The reference configuration is IP65.
11. What certifications are specified for the reference product?
The reference project specification lists CE (LVD + EMC), RoHS and ErP.
12. What energy savings can industrial LED retrofits achieve?
Energy savings vary by project. The Saint-Étienne reference project reported a 25% energy-saving improvement, but this should not be treated as a universal guarantee.
13. What engineering services does LIKELITE provide?
Services include Lighting and Circuitry Design, Onsite Metering, DIALux Evo Layout, LitePro DLX Layout, AutoCAD Layout, AGi32 Layout and Project Installation.
14. Can LIKELITE design lighting for an existing factory?
Yes. Existing facility dimensions, mounting conditions, equipment layout, lighting performance and electrical conditions can be evaluated before the new LED system is configured.
15. Can LIKELITE supply industrial lighting in bulk?
Yes. LIKELITE supports bulk industrial lighting supply for EPC contractors, engineering companies, distributors, project buyers and industrial facility upgrades.
Request an Industrial Lighting Solution
For an industrial workshop, factory, warehouse or production facility, LIKELITE can support:
Assessment → Measurement → Lighting Design → Simulation → Product Configuration → Smart Control → Supply → Installation
To prepare a project configuration, provide:
Facility dimensions
Mounting height
Existing lighting wattage
Existing fixture quantity
Working area
Production layout
Operating hours
Input voltage
Required lighting level
Smart-control requirements
Certification requirements
Project quantity
Installation requirements
LIKELITE
Outdoor LED Lighting Manufacturer & Project Solution Provider
LED Flood Lights | LED Street Lights | Solar Street Lights | LED Highway Lights | LED Stadium Lights | LED High Bay Lights | LED Wall Pack Lights
Request Industrial Lighting Design → Get Project Configuration → Request Quotation






