LED Lighting Solutions for Industrial Workshops, Manufacturing Facilities & Large Indoor Workspaces

Industrial workshops require lighting systems that provide sufficient illumination, stable operation, reliable protection and controllable energy consumption.

LIKELITE provides industrial LED lighting solutions for workshops, manufacturing facilities, warehouses, production areas and other large industrial spaces.

The solution combines:

LED Flood Lights + Lighting Design + Photometric Calculation + Smart Control + Electrical Design + Installation Support

A representative industrial workshop lighting configuration uses 150W LED Flood Lights, with 130 lm/W luminous efficiency, IP65 protection, 10KV surge protection and intelligent lighting control.


Industrial Workshop Lighting Challenges

Industrial lighting is not simply a matter of replacing high-wattage lamps with LED fixtures.

A practical workshop lighting system needs to consider:

  • Existing lighting conditions

  • Workshop dimensions

  • Mounting height

  • Beam distribution

  • Working areas

  • Production equipment

  • Worker visibility

  • Required illumination

  • Electrical infrastructure

  • Operating hours

  • Energy consumption

  • Motion and occupancy

  • Maintenance access

  • Environmental conditions

For industrial facilities, the lighting layout should be designed around the actual working environment.


LIKELITE Industrial Lighting Solution

150W LED Flood Lights + Smart Lighting Control

The reference configuration for industrial workshop applications uses:

150W LED Flood Lights

with:

130 lm/W luminous efficiency

IP65 protection

10KV surge protection

CREE SMD3030 LED

and:

Microwave Motion Sensor + Light Control + Timer Control

The configuration is suitable for industrial workshops where general area lighting, energy reduction and operating control are required.


Industrial Lighting Design Process

01 — Existing Lighting Assessment

The first step is to understand the existing facility.

LIKELITE can assess:

  • Existing luminaires

  • Existing wattage

  • Mounting positions

  • Lighting levels

  • Electrical supply

  • Operating schedules

  • Working zones

  • Maintenance conditions


02 — Onsite Metering

Onsite measurement can be used to establish the existing lighting condition.

Typical measurements may include:

Illuminance

Uniformity

Existing power consumption

Lighting operating hours

Electrical parameters

The measured information provides the basis for the replacement lighting design.


03 — Workshop Lighting Layout

The workshop geometry is converted into a lighting layout.

The design considers:

  • Length

  • Width

  • Ceiling height

  • Mounting height

  • Luminaire spacing

  • Working areas

  • Equipment arrangement

  • Light distribution

The objective is to achieve an appropriate lighting arrangement rather than simply maximizing lumen output.


Photometric Design

DIALux Evo / Litepro DLX / AGi32

LIKELITE can support industrial lighting calculations using:

DIALux Evo

For workshop lighting simulation, luminaire positioning and illumination analysis.

Litepro DLX

For alternative photometric calculations and layout development.

AGi32

For professional lighting analysis and project-specific calculations.

AutoCAD

For engineering layouts and installation drawings.


Industrial Lighting Distribution

120° Beam Angle

The reference LED Flood Light configuration uses a:

120° beam angle

The appropriate beam distribution depends on:

  • Mounting height

  • Ceiling structure

  • Equipment position

  • Working plane

  • Required illumination

  • Luminaire spacing

For large workshops, lighting distribution should be verified through photometric calculation before final production quantities are confirmed.


Smart Industrial Lighting Control

Microwave Motion Sensor + Light Control + Timer Control

Industrial workshops often have different operating periods and occupancy conditions.

LIKELITE can integrate three control functions.

Microwave Motion Sensor

Lighting can respond to detected movement within the controlled area.

Light Control

Lighting operation can be coordinated with ambient light conditions.

Timer Control

Operating schedules can be configured according to predetermined time periods.

The control strategy can be adapted according to the actual workshop operation.


Energy-Saving Strategy

Reduce Lighting Energy Without Compromising Required Illumination

Energy savings should be evaluated at system level.

The calculation should consider:

Existing Lighting Power

LED Replacement Power

Operating Hours

Control Strategy

Annual Energy Consumption

The reference industrial workshop configuration uses:

150W LED Flood Lights

130 lm/W

plus:

Microwave Motion Sensor + Light Control + Timer Control

A reference industrial lighting application supplied by the customer indicates:

20% Energy-Saving Improvement

The actual energy-saving result of a new project should be verified against the existing lighting system, operating schedule and measured energy consumption.


Industrial Lighting Application Areas

LIKELITE industrial LED lighting solutions can be configured for:

Manufacturing Workshops

General production-area illumination.

Industrial Workshops

Large working spaces requiring reliable area lighting.

Assembly Areas

Lighting for assembly and production operations.

Maintenance Workshops

Lighting for equipment maintenance and repair areas.

Warehouses

Lighting for storage and circulation areas.

Industrial Service Areas

Lighting for technical and operational spaces.

Large Indoor Facilities

Lighting for large open working environments.


Industrial Lighting Configuration

LED Flood Light

Power: 150W

LED Source: CREE SMD3030

Luminous Efficiency: 130 lm/W

Beam Angle: 120°

CCT: 5000K ±400K

CRI: Ra 80

The configuration is designed for general industrial lighting applications.


Electrical Performance

Input Voltage: AC 90–305V

Power Supply: AC

Frequency: 47–63Hz

Surge Protection: 10KV

Voltage Resistance: 1.5KV

The wide input-voltage range supports industrial facilities with varying AC supply conditions.


Industrial Environmental Protection

IP65 Protection

The reference LED Flood Light uses an IP65 protection rating, suitable for many industrial indoor and semi-outdoor environments.

The final protection requirement should be selected according to:

  • Dust conditions

  • Moisture

  • Cleaning methods

  • Installation location

  • Workshop environment


Thermal & Mechanical Configuration

Lamp Body: Aluminum alloy

Material: ALU+PC

Lifespan: 30,000 hours

Working Temperature: -20°C to 45°C

The aluminum alloy housing provides the mechanical structure for the industrial LED Flood Light.


Compliance

The reference configuration includes:

CE — LVD + EMC

RoHS

ErP

RED

The exact compliance documentation should be confirmed according to the final product configuration and project procurement requirements.


Industrial Lighting Engineering Services

LIKELITE can provide an integrated engineering service package:

Lighting & Circuitry Design

Lighting and electrical system design.

Onsite Metering

Measurement of existing lighting conditions.

DIALux Evo Layout

Photometric simulation and lighting layout.

Litepro DLX Layout

Lighting calculation and layout support.

AGi32 Layout

Professional photometric calculation.

AutoCAD Layout

Engineering drawing and installation layout.

Project Installation

Installation support for Industrial Lighting Projects.


Industrial Lighting Solution Workflow

STEP 01

Facility Information

Workshop dimensions / height / existing lighting / operating conditions

STEP 02

Onsite Assessment

Lighting / electrical / mounting conditions

STEP 03

Lighting Calculation

DIALux Evo / Litepro DLX / AGi32

STEP 04

Luminaire Selection

150W LED Flood Lights

STEP 05

Control Configuration

Motion Sensor + Light Control + Timer Control

STEP 06

Technical Confirmation

Lighting performance / electrical specifications / quantity

STEP 07

Production & Delivery

Bulk manufacturing and project supply

STEP 08

Installation Support

Installation and technical assistance

STEP 09

Performance Verification

Lighting and energy-performance verification


Reference Industrial Workshop Configuration

Greece — Piraeus Industrial Workshop Application

A representative industrial workshop lighting application in Piraeus, Greece uses the following configuration:

ItemSpecification
ProductLED Flood Lights
Power150W
ApplicationIndustrial Workshops
Quantity Reference1,200 sets
Energy-Saving Improvement20%
Smart ControlMicrowave Motion Sensor + Light Control + Timer Control
LED SourceCREE SMD3030
Efficiency130 lm/W
Beam Angle120°
Input VoltageAC 90–305V
IP RatingIP65
Surge Protection10KV
Voltage Resistance1.5KV
CCT5000K ±400K
CRIRa 80
MaterialALU+PC
Lamp BodyAluminum alloy
Lifespan30,000 hours
Frequency47–63Hz
Working Temperature-20°C to 45°C
ComplianceCE / RoHS / ErP / RED
Warranty2 years
OriginGuangdong, China
BrandLIKELITE

This configuration demonstrates how an industrial lighting solution can combine LED efficiency, lighting calculation, electrical design and intelligent control within a large workshop environment.


Technical Specification

ParameterSpecification
ProductLED Flood Lights
Power150W
Input VoltageAC 90–305V
IP RatingIP65
LED SourceCREE SMD3030
Beam Angle120°
Efficiency130 lm/W
Surge10KV
Voltage Resistance1.5KV
CCT5000K ±400K
CRIRa 80
MaterialALU+PC
Lamp BodyAluminum alloy
Lifespan30,000 hours
Power SupplyAC
Frequency47–63Hz
Working Temperature-20°C to 45°C
Smart ControlMicrowave Motion Sensor + Light Control + Timer Control
ComplianceCE / LVD+EMC / RoHS / ErP / RED
Warranty2 years
Package Size22 × 10 × 8 cm
Gross Weight9.55 kg
OriginGuangdong, China
BrandLIKELITE

Industrial Lighting Solutions FAQ

1. What is an industrial lighting solution?

An industrial lighting solution combines LED luminaires, lighting design, photometric calculations, electrical design, controls and installation support according to the requirements of an industrial facility.

2. What type of LED lighting is suitable for industrial workshops?

LED Flood Lights can be used for many workshop applications. The correct wattage and beam distribution should be selected according to mounting height, working area and required illumination.

3. Why use 150W LED Flood Lights?

A 150W configuration can provide a high-output lighting option for industrial areas. Final wattage should be determined through project-specific photometric calculations.

4. What LED source is used in the reference configuration?

The reference configuration uses CREE SMD3030 LED.

5. What is the luminous efficiency?

The specified luminous efficiency is 130 lm/W.

6. What is the beam angle?

The reference configuration uses a 120° beam angle.

7. Can LIKELITE perform DIALux calculations?

Yes. LIKELITE can provide DIALux Evo, Litepro DLX and AGi32 lighting calculation support.

8. Can LIKELITE perform onsite measurements?

Yes. Onsite metering can be included in the engineering service according to project requirements.

9. Can industrial lighting use motion sensors?

Yes. Microwave motion sensors can be integrated where the facility's operating conditions make occupancy-based lighting control appropriate.

10. Can timer control be integrated?

Yes. Timer Control can be combined with motion sensing and light-control functions.

11. What IP rating does the reference LED Flood Light use?

The reference configuration uses IP65.

12. What surge protection is specified?

The reference configuration provides 10KV surge protection.

13. What compliance standards are referenced?

The supplied configuration references CE (LVD + EMC), RoHS, ErP and RED.

14. What is the warranty period?

The reference configuration specifies a 2-year warranty.

15. Can LIKELITE design a complete industrial lighting system?

Yes. LIKELITE can support lighting design, onsite metering, DIALux Evo / Litepro DLX / AGi32 calculations, AutoCAD layouts, product supply and installation support.


Request an Industrial Lighting Assessment

For an industrial workshop lighting project, send LIKELITE:

Workshop Dimensions + Mounting Height + Existing Lighting + Working Areas + Operating Hours + Electrical Supply + Target Illumination + Quantity + Control Requirements

LIKELITE can evaluate the application and provide:

LED Flood Lights + Photometric Design + Smart Lighting Control + Electrical Design + Project Supply

LIKELITE

Industrial LED Lighting Manufacturer & Engineering Solution Provider