Outdoor sports venues require lighting systems that provide high output, controlled beam distribution, stable operation and consistent illumination across the playing area.
LIKELITE provides LED Stadium Lighting Solutions for football fields, outdoor sports grounds, training facilities, community sports venues, stadiums and large recreational areas.
The solution combines:
LED Stadium Lights + Lighting Design + Photometric Calculation + Electrical Design + Dimming + Installation Support
A representative outdoor sports venue configuration uses:
300W LED Stadium Lights
with:
150 lm/W luminous efficiency
IP66 / IK09 protection
OSRAM SMD2835 LED
and:
Dimming Support
Stadium Lighting Requirements
Sports lighting is different from general outdoor floodlighting.
A stadium lighting system must consider:
Playing area dimensions
Pole or mounting height
Luminaire positioning
Beam angle
Lighting uniformity
Glare control
Player visibility
Spectator visibility
Camera requirements
Competition level
Training requirements
Operating schedules
Dimming requirements
Electrical infrastructure
The lighting system should therefore be designed around the actual sports venue rather than selected only according to luminaire wattage.
LIKELITE Stadium Lighting Solution
300W LED Stadium Lights
The reference configuration uses:
300W LED Stadium Lights
150 lm/W luminous efficiency
OSRAM SMD2835 LED
120° beam angle
IP66 / IK09
PF 0.95
4KV surge protection
and:
Dimming Support
This configuration is suitable for a range of outdoor sports lighting applications where high brightness, lightweight construction and controllable output are required.
Stadium Lighting Design Process
01 — Venue Assessment
The lighting design starts with the actual sports facility.
Key information includes:
Field dimensions
Pole positions
Mounting height
Existing luminaires
Existing electrical system
Playing level
Operating hours
Spectator areas
Camera requirements
02 — Onsite Metering
Existing lighting conditions can be measured before an upgrade.
Typical measurements include:
Illuminance
Uniformity
Existing Lighting Power
Electrical Parameters
The measured data provides a reference for the new lighting design.
03 — Lighting Layout
The stadium geometry and lighting positions are established before final luminaire selection.
The design considers:
Pole Position
→
Mounting Height
→
Beam Distribution
→
Aiming Angle
→
Playing Area Coverage
→
Illumination Uniformity
Stadium Photometric Calculation
DIALux Evo / Litepro DLX / AGi32
LIKELITE can provide professional lighting calculation support.
DIALux Evo
Used for stadium and sports-field lighting simulation, luminaire positioning and illumination analysis.
Litepro DLX
Used for lighting layout and photometric calculation.
AGi32
Used for professional lighting analysis and project-specific calculations.
AutoCAD
Used for engineering layouts, pole positions and installation drawings.
Beam Distribution
120° Beam Angle
The reference stadium lighting configuration uses a:
120° beam angle
The appropriate beam distribution depends on the stadium geometry and luminaire mounting position.
Important factors include:
Mounting height
Pole distance
Field dimensions
Luminaire aiming
Required illumination
Uniformity
Glare considerations
For stadium projects, final aiming and luminaire quantity should be confirmed through photometric calculation.
Dimming & Lighting Control
Adjustable Lighting Output
The reference LED Stadium Light:
Supports Dimming
Dimming can be used where the venue has different operating conditions, such as:
Training
Practice
General use
Match operation
Maintenance
Partial-field operation
The control strategy should be designed according to the venue's actual electrical and operating requirements.
High-Brightness Stadium Lighting
150 lm/W
The reference configuration provides:
150 lm/W luminous efficiency
combined with:
300W LED output
and:
OSRAM SMD2835 LED
The high-output configuration is intended to provide an efficient lighting option for large outdoor sports areas.
Final luminaire quantity and positioning should be established through project-specific photometric calculations.
Stadium Lighting Applications
LIKELITE stadium lighting solutions can be configured for:
Football Fields
Lighting for outdoor football and soccer facilities.
Training Grounds
Adjustable lighting for sports training areas.
Community Sports Grounds
Lighting for public and municipal sports facilities.
Outdoor Sports Venues
General lighting for outdoor recreational sports areas.
Tennis Facilities
High-output lighting for tennis courts and surrounding areas.
Basketball Courts
Outdoor basketball court lighting applications.
Athletics Facilities
Lighting support for athletics and multi-purpose sports facilities.
Stadiums
Large-area sports lighting requiring coordinated luminaire layouts.
Stadium Lighting Configuration
300W LED Stadium Light
| Parameter | Specification |
|---|---|
| Product | LED Stadium Lights |
| Power | 300W |
| LED Source | OSRAM SMD2835 |
| Luminous Efficiency | 150 lm/W |
| Beam Angle | 120° |
| Input Voltage | AC 85–305V |
| IP Rating | IP66 |
| Impact Protection | IK09 |
| CCT | 5000K ±300K |
| CRI | Ra 70 |
| Dimming | Supported |
| PF | 0.95 |
| Surge Protection | 4KV |
| Material | Aluminum |
| Housing | Die Casting Aluminum ADC12 |
| Lens | PC Lens + Glass |
| Lifespan | 30,000 hours |
| Frequency | 50/60Hz |
| Working Temperature | -35°C to 45°C |
| Weight | 9.55 kg |
| Warranty | 2 years |
| Compliance | CE / RoHS / ENEC |
| Brand | LIKELITE |
| Origin | Guangdong, China |
Stadium Lighting Engineering Services
LIKELITE provides a complete engineering service package:
Lighting & Circuitry Design
Lighting and electrical design according to venue requirements.
Onsite Metering
Existing lighting assessment and onsite measurement.
DIALux Evo Layout
Photometric calculation and lighting simulation.
Litepro DLX Layout
Alternative lighting calculation and layout support.
AGi32 Layout
Professional photometric analysis.
AutoCAD Layout
Engineering drawings and installation layouts.
Project Installation
Installation support for stadium lighting projects.
Stadium Lighting Energy Strategy
Efficient Lighting + Dimming
Energy consumption should be evaluated at system level.
The basic assessment includes:
Existing Lighting Power
↓
New LED Lighting Power
↓
Operating Hours
↓
Dimming Schedule
↓
Annual Energy Consumption
A reference outdoor sports lighting application supplied for Bilbao, Spain indicates:
300W LED Stadium Lights
200 sets
150 lm/W
with:
20% Energy-Saving Improvement
This figure should be treated as the supplied reference application result. Actual energy savings depend on the existing lighting system, operating hours, dimming schedule and final lighting design.
Stadium Lighting Safety & Protection
IP66 / IK09
The reference LED Stadium Light provides:
IP66
and:
IK09
protection.
The housing uses:
Die Casting Aluminum ADC12
with:
PC Lens + Glass
The configuration is designed for demanding outdoor sports lighting environments.
Electrical Performance
Input Voltage: AC 85–305V
Frequency: 50/60Hz
PF: 0.95
Surge Protection: 4KV
The wide input-voltage range provides flexibility for different AC electrical conditions.
Environmental Performance
Working Temperature: -35°C to 45°C
Lifespan: 30,000 hours
Housing: Die Casting Aluminum ADC12
Lens: PC Lens + Glass
The operating temperature range allows the configuration to be considered for outdoor sports facilities exposed to variable environmental conditions.
European Compliance
The reference product configuration includes:
CE
RoHS
ENEC
Final certification documentation should be confirmed against the exact production configuration supplied for the project.
Reference Stadium Lighting Application
Bilbao, Spain — Outdoor Sports Venue
The reference application is an outdoor sports lighting upgrade in:
Bilbao, Spain
Configuration:
| Item | Reference Data |
|---|---|
| Application | Outdoor Sports Venue |
| Product | LED Stadium Lights |
| Power | 300W |
| Quantity | 200 sets |
| Efficiency | 150 lm/W |
| Energy-Saving Improvement | 20% |
| LED Source | OSRAM SMD2835 |
| Beam Angle | 120° |
| IP Rating | IP66 |
| IK Rating | IK09 |
| CCT | 5000K ±300K |
| CRI | Ra 70 |
| Dimming | Supported |
| PF | 0.95 |
| Surge Protection | 4KV |
| Input Voltage | AC 85–305V |
| Frequency | 50/60Hz |
| Lifespan | 30,000 hours |
| Working Temperature | -35°C to 45°C |
| Material | Die Casting Aluminum ADC12 |
| Compliance | CE / RoHS / ENEC |
| Warranty | 2 years |
| Brand | LIKELITE |
| Origin | Guangdong, China |
The Bilbao application demonstrates how a stadium lighting system can combine high-output LED technology, photometric design, dimming capability and outdoor protection.
Stadium Lighting Solution Workflow
STEP 01
Venue Information
Field dimensions / pole positions / mounting height / existing lighting
↓
STEP 02
Site Assessment
Lighting / electrical / installation conditions
↓
STEP 03
Photometric Calculation
DIALux Evo / Litepro DLX / AGi32
↓
STEP 04
Luminaire Selection
300W LED Stadium Lights
↓
STEP 05
Beam & Aiming Design
Beam distribution / aiming angle / field coverage
↓
STEP 06
Dimming Configuration
Training / match / maintenance / partial operation
↓
STEP 07
Engineering Confirmation
Lighting performance / electrical design / quantity
↓
STEP 08
Production & Delivery
Bulk stadium lighting supply
↓
STEP 09
Installation & Verification
Installation / aiming / lighting verification
Stadium Lighting Solutions FAQ
1. What is a stadium lighting solution?
A stadium lighting solution combines LED luminaires, photometric calculations, beam distribution, aiming, electrical design, dimming and installation support for sports facilities.
2. What type of LED lights are used for outdoor stadiums?
LED Stadium Lights are commonly used for large outdoor sports areas. Wattage, beam distribution and quantity should be determined according to the venue.
3. What wattage is the reference LIKELITE stadium light?
The reference configuration uses 300W LED Stadium Lights.
4. What is the luminous efficiency?
The specified luminous efficiency is 150 lm/W.
5. Does the stadium light support dimming?
Yes. The reference configuration supports dimming.
6. What LED source is used?
The reference product uses OSRAM SMD2835 LED.
7. What is the beam angle?
The reference configuration uses a 120° beam angle.
8. What protection rating does the product have?
The specified protection is IP66 / IK09.
9. Can LIKELITE provide DIALux stadium lighting calculations?
Yes. LIKELITE can provide DIALux Evo, Litepro DLX and AGi32 calculation support.
10. Can LIKELITE perform onsite measurements?
Yes. Onsite Metering can be included according to project requirements.
11. What input voltage does the stadium light support?
The reference product supports AC 85–305V.
12. What is the surge protection level?
The specified surge protection is 4KV.
13. What certifications are available?
The reference configuration includes CE, RoHS and ENEC.
14. What is the warranty?
The reference product specification provides a 2-year warranty.
15. Can LIKELITE design a complete stadium lighting system?
Yes. Services include lighting and circuitry design, onsite metering, DIALux Evo, Litepro DLX, AGi32, AutoCAD layouts, product supply and installation support.
Request a Stadium Lighting Design
For a new stadium or sports-field lighting upgrade, provide:
Field Dimensions + Pole Layout + Mounting Height + Existing Lighting + Required Lighting Level + Operating Mode + Dimming Requirements
LIKELITE can provide:
LED Stadium Lights + Photometric Calculation + Beam/Aiming Design + Dimming Configuration + Engineering Layout + Project Supply
LIKELITE