Riyadh Outdoor Sports Venue Lighting Upgrade Project

300 Sets of 200W LED Stadium Lights for Outdoor Sports Lighting Modernization in Riyadh, Saudi Arabia

LIKELITE supplied a complete LED stadium lighting solution for an outdoor sports venue lighting upgrade project in Riyadh, Saudi Arabia. The project included 300 sets of 200W LED Stadium Lights, with dimming capability, IP66/IK09 protection and engineering lighting design support.

The project was developed around the requirements of high-brightness outdoor sports lighting, reliable operation in demanding environmental conditions, controlled energy consumption and professional lighting design. LIKELITE supported the project with lighting and circuitry design, onsite metering, lighting simulation and project installation services.

Project Information

Project ItemProject Details
Project LocationRiyadh, Saudi Arabia
ApplicationOutdoor Sports Venue Lighting Upgrade
Project TypeStadium / Sports Venue Lighting Project
ProductLED Stadium Lights
Power200W
Quantity300 sets
Reported Energy-Saving Effect20%
CertificationCB / SASO / SIRC / SABER
Warranty2 years
BrandLIKELITE
OriginGuangdong, China

Project Scope

The Riyadh project focused on upgrading outdoor sports venue lighting with high-output LED stadium lighting equipment.

The project scope included:

  • Supply of 300 sets of 200W LED Stadium Lights

  • Outdoor sports venue lighting application

  • Lighting and circuitry design

  • Onsite lighting measurement

  • DIALux Evo lighting layout

  • LitePro DLX lighting layout

  • AutoCAD lighting layout

  • AGi32 lighting layout

  • Dimming support

  • Project installation support

  • Product compliance documentation

  • Two-year warranty support

The project combines product supply with lighting engineering services rather than treating the stadium luminaires as standalone products.

LED Stadium Light Configuration

The project used 200W LED Stadium Lights configured for high-output outdoor applications.

Key equipment specifications included:

  • Rated Power: 200W

  • Input Voltage: AC 120–277V

  • Frequency: 60Hz

  • Power Factor: PF 0.95

  • Luminous Efficiency: 170 lm/W

  • Light Source: OSRAM SMD3030 LED

  • Beam Angle: 120°

  • Color Temperature: 5000K ±300K

  • Color Rendering Index: Ra 80

  • IP Rating: IP66

  • Impact Protection: IK09

  • Surge Protection: 4KV

  • Lifespan: 30,000 hours

  • Dimming: Supported

  • Housing Material: Die-cast aluminum ADC12

  • Lens: PC lens + glass

  • Working Temperature: -35°C to 45°C

  • Product Weight: 11.55 kg

  • Brand: LIKELITE

Outdoor Sports Venue Lighting Application

Outdoor sports facilities require lighting equipment that can operate reliably under changing weather and environmental conditions while providing sufficient brightness across the playing and activity areas.

For this Riyadh project, the LED Stadium Lights were configured with IP66/IK09 protection, aluminum housing and a working temperature range of -35°C to 45°C.

The 120° beam angle provides a wide lighting distribution option for outdoor venue applications. Final lighting performance, uniformity and mounting configuration depend on the actual venue geometry, mounting height, aiming direction and lighting design.

Dimming and Lighting Control

The 200W LED Stadium Lights used in the project support dimming.

Dimming capability can be incorporated into sports venue lighting control according to operating requirements, allowing lighting levels to be adjusted for different usage conditions.

For a project application, the final control configuration should be coordinated with:

  • Venue operating schedules

  • Sports activity requirements

  • Lighting zones

  • Required lighting levels

  • Energy management objectives

  • Control system compatibility

  • Installation configuration

LIKELITE provides the lighting design and circuitry design support required to coordinate the lighting equipment with the project application.

Lighting Design and Engineering Services

The Riyadh project included multiple professional lighting design and engineering services.

Lighting and Circuitry Design

LIKELITE supports electrical and lighting planning for the stadium lighting installation, including luminaire positioning and circuitry coordination.

Onsite Metering

Onsite metering can be used to collect actual project conditions before finalizing the lighting design.

DIALux Evo Layout

DIALux Evo can be used to develop and evaluate the proposed stadium lighting layout based on the project geometry and luminaire configuration.

LitePro DLX Layout

LitePro DLX provides another lighting design environment for project-specific lighting calculations and layout development.

AutoCAD Layout

AutoCAD drawings can be used to coordinate lighting positions and installation requirements with project drawings.

AGi32 Layout

AGi32 can support lighting calculation and design coordination where required by the project.

Project Installation

LIKELITE also provides project installation support as part of its lighting engineering service capability.

Lighting Performance Configuration

The project luminaires provide a stated luminous efficiency of 170 lm/W.

Combined with OSRAM SMD3030 LED technology, a 5000K ±300K color temperature and Ra 80 color rendering index, the equipment was configured for high-brightness outdoor lighting applications.

The actual illumination results of a sports venue depend on the complete lighting system rather than luminaire efficacy alone.

Important project variables include:

  • Mounting height

  • Luminaire quantity

  • Beam angle

  • Aiming angle

  • Pole or structure location

  • Venue geometry

  • Target lighting requirements

  • Existing lighting conditions

  • Lighting control settings

For this reason, project-specific DIALux Evo, LitePro DLX or AGi32 calculations should be used when formal lighting performance verification is required.

Energy-Saving Performance

The project information indicates a 20% energy-saving effect following the lighting upgrade.

The energy-saving result should be evaluated against the actual operating conditions and the original lighting system, including:

  • Existing fixture power

  • Operating hours

  • Lighting schedules

  • Number of operating fixtures

  • Dimming settings

  • Control strategy

  • Actual electricity consumption

The 20% figure should therefore be treated as the project-reported energy-saving result rather than a universal performance guarantee for every stadium application.

Saudi Arabia Compliance and Documentation

The Riyadh project included the following certification and compliance references:

  • CB

  • SASO

  • SIRC

  • SABER

These documents support project procurement and compliance requirements for the Saudi Arabian market.

For project procurement, the applicable certification and documentation package should be confirmed against the specific project, product model and purchasing requirements before shipment.

Designed for Riyadh Outdoor Conditions

The project equipment was configured for demanding outdoor operating conditions.

The luminaire housing uses die-cast aluminum ADC12, combined with a PC lens and glass construction.

The stated operating temperature range is:

-35°C to 45°C

The combination of IP66 protection, IK09 impact protection and aluminum construction provides a configuration intended for outdoor sports lighting applications.

The equipment also includes 4KV surge protection and a stated PF of 0.95.

Installation and Project Execution

For a stadium lighting project, equipment supply is only one part of the delivery process.

LIKELITE's project service structure can include:

1. Project Requirement Review

Review the venue application, lighting objectives, installation conditions and electrical requirements.

2. Onsite Measurement

Collect site information required for lighting design and equipment positioning.

3. Lighting Design

Develop the proposed lighting layout using DIALux Evo, LitePro DLX, AutoCAD or AGi32 according to project requirements.

4. Equipment Configuration

Confirm LED power, beam angle, protection rating, electrical parameters, dimming requirements and project documentation.

5. Production and Inspection

Prepare the specified LED Stadium Lights according to the approved project configuration.

6. Delivery

Coordinate project packaging and shipment for the required quantity.

7. Installation

Provide project installation support according to the agreed project scope.

Before & After Comparison



DIALux EVO Lighting Simulation Verification

Project Data at a Glance

Location: Riyadh, Saudi Arabia
Application: Outdoor Sports Venue
Project: Stadium Lighting Upgrade
Product: LED Stadium Lights
Power: 200W
Quantity: 300 sets
Luminous Efficiency: 170 lm/W
LED: OSRAM SMD3030
Beam Angle: 120°
CCT: 5000K ±300K
CRI: Ra 80
Protection: IP66 / IK09
Surge Protection: 4KV
Dimming: Yes
Working Temperature: -35°C to 45°C
Lifespan: 30,000 hours
Power Factor: 0.95
Certification: CB / SASO / SIRC / SABER
Warranty: 2 years
Energy-Saving Effect: 20% reported
Engineering Services: Lighting Design / Onsite Metering / DIALux Evo / LitePro DLX / AutoCAD / AGi32 / Project Installation

Why This Project Matters for Stadium Lighting Procurement

This Riyadh project demonstrates a project-oriented approach to outdoor sports venue lighting.

The project combines:

  • 200W LED Stadium Lights

  • 300-set project quantity

  • 170 lm/W stated luminous efficiency

  • OSRAM SMD3030 LED

  • IP66 / IK09 protection

  • Dimming capability

  • Saudi market certification references

  • Lighting design services

  • Multiple professional lighting calculation platforms

  • Project installation support

  • Two-year warranty

For EPC contractors, engineering companies, sports facility operators and bulk project buyers, these elements provide a structured basis for reviewing stadium lighting equipment and project delivery capability.

Stadium Lighting Project FAQ

1. What LED stadium lights were supplied for the Riyadh project?

The project used 200W LED Stadium Lights supplied under the LIKELITE brand.

2. How many LED stadium lights were included in the project?

The project quantity was 300 sets.

3. What is the luminous efficiency of the stadium lights?

The stated lamp luminous efficiency is 170 lm/W.

4. Which LED chip is used?

The project specification uses OSRAM SMD3030 LED.

5. Are the stadium lights suitable for outdoor applications?

The luminaires are specified with IP66 and IK09 protection and a working temperature range of -35°C to 45°C for outdoor applications.

6. Do the LED Stadium Lights support dimming?

Yes. The specified stadium lights support dimming.

7. What certifications were specified for the Saudi project?

The project certification references are CB, SASO, SIRC and SABER.

8. What was the reported energy-saving effect?

The project information indicates a 20% energy-saving effect. Actual savings depend on the existing lighting system, operating hours and control strategy.

9. What lighting design software can LIKELITE support?

The project service scope includes DIALux Evo, LitePro DLX, AutoCAD and AGi32 layouts.

10. Does LIKELITE provide onsite lighting measurement?

Yes. Onsite metering is included in the listed lighting solutions service.

11. Does LIKELITE provide installation support?

Yes. Project installation is included in the stated engineering service scope.

12. What beam angle is specified for the stadium lights?

The specified beam angle is 120°.

13. What is the protection rating?

The project luminaires are specified as IP66 with IK09 impact protection.

14. What is the warranty period?

The project specification includes a two-year warranty.

15. Can LIKELITE support similar stadium lighting projects?

LIKELITE can provide LED Stadium Lights together with lighting and circuitry design, onsite metering, lighting simulation layouts and project installation services for outdoor sports lighting projects.

Start an Outdoor Stadium Lighting Project

For stadiums, sports grounds and outdoor sports venues requiring LED lighting upgrades, LIKELITE can support the project from lighting requirements and onsite measurement through lighting design, product configuration and installation.

Project requirements can include:

  • Venue location

  • Existing lighting system

  • Required LED lighting power

  • Quantity

  • Mounting height

  • Existing poles or structures

  • Electrical conditions

  • Dimming requirements

  • Lighting design requirements

  • Certification requirements

  • Project quantity

  • Installation scope

LIKELITE — Outdoor LED Lighting Engineering Project Solution Provider

LED Stadium Lights | Stadium Lighting Projects | Sports Venue Lighting | Outdoor Sports Lighting | Lighting Design | Project Installation