300 Sets of 200W LED Stadium Lights for Outdoor Sports Lighting Modernization in Riyadh, Saudi Arabia
LIKELITE supplied a complete LED stadium lighting solution for an outdoor sports venue lighting upgrade project in Riyadh, Saudi Arabia. The project included 300 sets of 200W LED Stadium Lights, with dimming capability, IP66/IK09 protection and engineering lighting design support.
The project was developed around the requirements of high-brightness outdoor sports lighting, reliable operation in demanding environmental conditions, controlled energy consumption and professional lighting design. LIKELITE supported the project with lighting and circuitry design, onsite metering, lighting simulation and project installation services.
The Riyadh project focused on upgrading outdoor sports venue lighting with high-output LED stadium lighting equipment.
The project scope included:
Supply of 300 sets of 200W LED Stadium Lights
Outdoor sports venue lighting application
Lighting and circuitry design
Onsite lighting measurement
DIALux Evo lighting layout
LitePro DLX lighting layout
AutoCAD lighting layout
AGi32 lighting layout
Dimming support
Project installation support
Product compliance documentation
Two-year warranty support
The project combines product supply with lighting engineering services rather than treating the stadium luminaires as standalone products.
LED Stadium Light Configuration
The project used 200W LED Stadium Lights configured for high-output outdoor applications.
Key equipment specifications included:
Rated Power: 200W
Input Voltage: AC 120–277V
Frequency: 60Hz
Power Factor: PF 0.95
Luminous Efficiency: 170 lm/W
Light Source: OSRAM SMD3030 LED
Beam Angle: 120°
Color Temperature: 5000K ±300K
Color Rendering Index: Ra 80
IP Rating: IP66
Impact Protection: IK09
Surge Protection: 4KV
Lifespan: 30,000 hours
Dimming: Supported
Housing Material: Die-cast aluminum ADC12
Lens: PC lens + glass
Working Temperature: -35°C to 45°C
Product Weight: 11.55 kg
Brand: LIKELITE
Outdoor Sports Venue Lighting Application
Outdoor sports facilities require lighting equipment that can operate reliably under changing weather and environmental conditions while providing sufficient brightness across the playing and activity areas.
For this Riyadh project, the LED Stadium Lights were configured with IP66/IK09 protection, aluminum housing and a working temperature range of -35°C to 45°C.
The 120° beam angle provides a wide lighting distribution option for outdoor venue applications. Final lighting performance, uniformity and mounting configuration depend on the actual venue geometry, mounting height, aiming direction and lighting design.
Dimming and Lighting Control
The 200W LED Stadium Lights used in the project support dimming.
Dimming capability can be incorporated into sports venue lighting control according to operating requirements, allowing lighting levels to be adjusted for different usage conditions.
For a project application, the final control configuration should be coordinated with:
Venue operating schedules
Sports activity requirements
Lighting zones
Required lighting levels
Energy management objectives
Control system compatibility
Installation configuration
LIKELITE provides the lighting design and circuitry design support required to coordinate the lighting equipment with the project application.
Lighting Design and Engineering Services
The Riyadh project included multiple professional lighting design and engineering services.
Lighting and Circuitry Design
LIKELITE supports electrical and lighting planning for the stadium lighting installation, including luminaire positioning and circuitry coordination.
Onsite Metering
Onsite metering can be used to collect actual project conditions before finalizing the lighting design.
DIALux Evo Layout
DIALux Evo can be used to develop and evaluate the proposed stadium lighting layout based on the project geometry and luminaire configuration.
LitePro DLX Layout
LitePro DLX provides another lighting design environment for project-specific lighting calculations and layout development.
AutoCAD Layout
AutoCAD drawings can be used to coordinate lighting positions and installation requirements with project drawings.
AGi32 Layout
AGi32 can support lighting calculation and design coordination where required by the project.
Project Installation
LIKELITE also provides project installation support as part of its lighting engineering service capability.
Lighting Performance Configuration
The project luminaires provide a stated luminous efficiency of 170 lm/W.
Combined with OSRAM SMD3030 LED technology, a 5000K ±300K color temperature and Ra 80 color rendering index, the equipment was configured for high-brightness outdoor lighting applications.
The actual illumination results of a sports venue depend on the complete lighting system rather than luminaire efficacy alone.
Important project variables include:
Mounting height
Luminaire quantity
Beam angle
Aiming angle
Pole or structure location
Venue geometry
Target lighting requirements
Existing lighting conditions
Lighting control settings
For this reason, project-specific DIALux Evo, LitePro DLX or AGi32 calculations should be used when formal lighting performance verification is required.
Energy-Saving Performance
The project information indicates a 20% energy-saving effect following the lighting upgrade.
The energy-saving result should be evaluated against the actual operating conditions and the original lighting system, including:
Existing fixture power
Operating hours
Lighting schedules
Number of operating fixtures
Dimming settings
Control strategy
Actual electricity consumption
The 20% figure should therefore be treated as the project-reported energy-saving result rather than a universal performance guarantee for every stadium application.
Saudi Arabia Compliance and Documentation
The Riyadh project included the following certification and compliance references:
CB
SASO
SIRC
SABER
These documents support project procurement and compliance requirements for the Saudi Arabian market.
For project procurement, the applicable certification and documentation package should be confirmed against the specific project, product model and purchasing requirements before shipment.
Designed for Riyadh Outdoor Conditions
The project equipment was configured for demanding outdoor operating conditions.
The luminaire housing uses die-cast aluminum ADC12, combined with a PC lens and glass construction.
The stated operating temperature range is:
-35°C to 45°C
The combination of IP66 protection, IK09 impact protection and aluminum construction provides a configuration intended for outdoor sports lighting applications.
The equipment also includes 4KV surge protection and a stated PF of 0.95.
Installation and Project Execution
For a stadium lighting project, equipment supply is only one part of the delivery process.
LIKELITE's project service structure can include:
1. Project Requirement Review
Review the venue application, lighting objectives, installation conditions and electrical requirements.
2. Onsite Measurement
Collect site information required for lighting design and equipment positioning.
3. Lighting Design
Develop the proposed lighting layout using DIALux Evo, LitePro DLX, AutoCAD or AGi32 according to project requirements.
4. Equipment Configuration
Confirm LED power, beam angle, protection rating, electrical parameters, dimming requirements and project documentation.
5. Production and Inspection
Prepare the specified LED Stadium Lights according to the approved project configuration.
6. Delivery
Coordinate project packaging and shipment for the required quantity.
7. Installation
Provide project installation support according to the agreed project scope.
Before & After Comparison DIALux EVO Lighting Simulation Verification
Why This Project Matters for Stadium Lighting Procurement
This Riyadh project demonstrates a project-oriented approach to outdoor sports venue lighting.
The project combines:
200W LED Stadium Lights
300-set project quantity
170 lm/W stated luminous efficiency
OSRAM SMD3030 LED
IP66 / IK09 protection
Dimming capability
Saudi market certification references
Lighting design services
Multiple professional lighting calculation platforms
Project installation support
Two-year warranty
For EPC contractors, engineering companies, sports facility operators and bulk project buyers, these elements provide a structured basis for reviewing stadium lighting equipment and project delivery capability.
Stadium Lighting Project FAQ
1. What LED stadium lights were supplied for the Riyadh project?
The project used 200W LED Stadium Lights supplied under the LIKELITE brand.
2. How many LED stadium lights were included in the project?
The project quantity was 300 sets.
3. What is the luminous efficiency of the stadium lights?
The stated lamp luminous efficiency is 170 lm/W.
4. Which LED chip is used?
The project specification uses OSRAM SMD3030 LED.
5. Are the stadium lights suitable for outdoor applications?
The luminaires are specified with IP66 and IK09 protection and a working temperature range of -35°C to 45°C for outdoor applications.
6. Do the LED Stadium Lights support dimming?
Yes. The specified stadium lights support dimming.
7. What certifications were specified for the Saudi project?
The project certification references are CB, SASO, SIRC and SABER.
8. What was the reported energy-saving effect?
The project information indicates a 20% energy-saving effect. Actual savings depend on the existing lighting system, operating hours and control strategy.
9. What lighting design software can LIKELITE support?
The project service scope includes DIALux Evo, LitePro DLX, AutoCAD and AGi32 layouts.
10. Does LIKELITE provide onsite lighting measurement?
Yes. Onsite metering is included in the listed lighting solutions service.
11. Does LIKELITE provide installation support?
Yes. Project installation is included in the stated engineering service scope.
12. What beam angle is specified for the stadium lights?
The specified beam angle is 120°.
13. What is the protection rating?
The project luminaires are specified as IP66 with IK09 impact protection.
14. What is the warranty period?
The project specification includes a two-year warranty.
15. Can LIKELITE support similar stadium lighting projects?
LIKELITE can provide LED Stadium Lights together with lighting and circuitry design, onsite metering, lighting simulation layouts and project installation services for outdoor sports lighting projects.
Start an Outdoor Stadium Lighting Project
For stadiums, sports grounds and outdoor sports venues requiring LED lighting upgrades, LIKELITE can support the project from lighting requirements and onsite measurement through lighting design, product configuration and installation.
Project requirements can include:
Venue location
Existing lighting system
Required LED lighting power
Quantity
Mounting height
Existing poles or structures
Electrical conditions
Dimming requirements
Lighting design requirements
Certification requirements
Project quantity
Installation scope
LIKELITE — Outdoor LED Lighting Engineering Project Solution Provider