LIKELITE supplied a 300W LED Stadium Lighting system for an outdoor sports facility lighting upgrade project in Iquitos, Peru.
The project was developed to replace or upgrade the existing outdoor lighting system with high-output LED luminaires capable of providing improved lighting performance while reducing energy consumption.
The supplied configuration consisted of 300 sets of 300W LED Stadium Lights, supported by project-specific lighting design, onsite measurement, lighting simulation and installation services.
Project Overview
Project Scope
The Iquitos project focused on the upgrade of an existing outdoor sports facility lighting system.
The project scope included:
LED stadium lighting supply
Lighting and circuitry design
Onsite metering
Lighting layout
DIALux Evo support
LitePro Dlx layout support
AutoCAD layout support
AGi32 layout support
Project installation support
Technical documentation
Project-based product configuration
The lighting equipment was selected according to the project's outdoor operating environment and high-output lighting requirements.
The project used a high-output 300W LED Stadium Light designed for large outdoor sports lighting applications.
The luminaire combines high luminous efficiency, outdoor protection, impact resistance and dimming capability.
Project Product Specifications
Parameter
Specification
Product
LED Stadium Lights
Power
300W
Input Voltage
220V AC
Frequency
60Hz
LED Source
OSRAM SMD3030
Luminous Efficiency
140 lm/W
Beam Angle
120°
CCT
5000K ±300K
CRI
Ra 70
IP Rating
IP66
IK Rating
IK09
Power Factor
PF 0.95
Surge Protection
4KV
Dimming
Supported
Lifespan
30,000 hours
Working Temperature
-35°C to +45°C
Housing
Die-cast Aluminum ADC12
Lens
PC Lens + Glass
Material
Aluminum
Product Weight
10.55 kg
Certification
INACAL
Warranty
2 Years
Project Engineering
Lighting & Circuitry Design
The project included lighting and circuitry design based on the outdoor sports facility requirements.
The engineering review considered:
Existing lighting conditions
Field configuration
Luminaire installation positions
Electrical supply
Luminaire quantity
Lighting distribution
Operating requirements
Maintenance considerations
The objective was to establish a practical lighting configuration suitable for the facility rather than selecting luminaires based solely on rated wattage.
Onsite Metering
Onsite metering was included as part of the project engineering process.
Site information is important for determining the actual lighting configuration, particularly when upgrading an existing sports facility.
The engineering team can evaluate:
Field dimensions
Pole locations
Mounting height
Existing luminaires
Existing electrical infrastructure
Installation conditions
Environmental factors
The measured data can then be used for lighting layout and product configuration.
DIALux Evo Lighting Design
DIALux Evo was used as part of the lighting design workflow.
Lighting simulation allows the project team to review the proposed luminaire arrangement before installation.
The calculation process can evaluate:
Illuminance distribution
Average illuminance
Uniformity
Lighting coverage
Luminaire positioning
Potential dark areas
Lighting distribution across the sports area
The final lighting layout should be confirmed according to the actual project requirements and available site data.
LitePro / AutoCAD / AGi32 Layout
The project engineering support also included compatibility with common professional lighting design and CAD workflows.
Available design support included:
LitePro Dlx Layout
AutoCAD Layout
AGi32 Layout
These formats can be used for coordination between lighting suppliers, electrical contractors, EPC teams and engineering consultants.
Installation
Project Installation Support
The project included project installation support.
For outdoor sports lighting upgrades, installation accuracy is important because the final lighting distribution depends not only on luminaire specifications but also on:
Mounting height
Installation position
Tilt angle
Pole arrangement
Beam direction
Electrical connection
Control configuration
The installation process should follow the approved lighting layout and project engineering requirements.
Project Performance
20% Energy-Saving Improvement
One of the key objectives of the Iquitos project was to improve lighting efficiency while controlling energy consumption.
The project reported:
20% Energy-Saving Improvement
The supplied lighting configuration consisted of:
300W × 300 sets
The energy-saving result should be evaluated against the project's previous lighting system, operating schedule and actual field conditions.
LED lighting efficiency, lighting layout and operating control all contribute to the final energy performance of an outdoor sports facility.
Outdoor Protection
IP66 + IK09
The Iquitos project required luminaires suitable for outdoor operating conditions.
The supplied LED Stadium Lights were specified with:
IP66
and:
IK09
protection.
The IP66 rating provides protection against dust ingress and powerful water jets.
The die-cast aluminum ADC12 housing provides structural protection and supports thermal management.
The specified operating temperature is:
-35°C to +45°C
Optical Configuration
120° Beam Angle
The project luminaires use a:
120° beam angle
configuration.
Beam distribution must be considered together with:
Pole height
Field dimensions
Luminaire spacing
Installation angle
Required lighting coverage
Uniformity requirements
For this reason, the final installation position and beam orientation should follow the approved lighting calculation rather than relying on beam angle alone.
Dimming Capability
The supplied 300W LED Stadium Lights support dimming.
This provides flexibility for different operating conditions.
Potential operating modes include:
Training
Recreation
Competition
Partial-field operation
Maintenance
Reduced-output operation
The actual dimming and control method depends on the project's electrical and control system.
Project Equipment Features
The supplied stadium lighting configuration was designed around several project requirements.
High Brightness
The 300W output and 140 lm/W luminous efficiency provide high-output illumination for large outdoor areas.
Lightweight Construction
The product weight is approximately:
10.55 kg
despite its high-output configuration.
Outdoor Protection
IP66 and IK09 protection provide enhanced suitability for outdoor applications.
High-Efficiency LED Source
The system uses:
OSRAM SMD3030 LED
with a specified luminous efficiency of:
140 lm/W
Dimming Support
Dimming capability provides additional flexibility for operational control.
Project Workflow
01 — Project Requirement Review
Review project location, sports facility type, existing lighting, field dimensions and lighting requirements.
02 — Site Measurement
Collect site and existing electrical information.
03 — Lighting Design
Develop the lighting and circuitry design.
04 — Product Configuration
Confirm the 300W LED Stadium Light configuration according to project requirements.
05 — Lighting Simulation
Prepare DIALux Evo and other required lighting layouts.
06 — Engineering Confirmation
Review lighting distribution, installation positions and electrical requirements.
07 — Production
Manufacture the project lighting equipment according to the approved configuration.
08 — Delivery
Prepare and deliver 300 sets of LED Stadium Lights.
09 — Installation
Complete project installation according to the approved design.
10 — Final Verification
Verify the installed lighting system against the project design and operating requirements.
Project Result
The Iquitos outdoor sports facility project delivered a high-output LED lighting configuration based on:
300W LED Stadium Lights
300 sets
140 lm/W
IP66 / IK09
OSRAM SMD3030
4KV Surge Protection
Dimming Support
with a reported:
20% Energy-Saving Improvement
The project provides a reference configuration for outdoor sports facilities requiring high-output LED lighting, outdoor protection and controlled energy consumption.
Before & After Comparison
DIALux EVO Lighting Simulation Verification
Why This Project Matters
The Iquitos project demonstrates the practical application of LED stadium lighting in a Latin American outdoor sports environment.
The project combines:
LED Product Supply
Lighting Engineering
Simulation
Installation Support
Project-Based Supply
This project structure is particularly relevant to EPC contractors, engineering companies, municipalities, sports facility operators and bulk lighting buyers evaluating LED stadium lighting suppliers.
Project Technical Summary
Location
Iquitos, Peru
Application
Outdoor Sports Facility
Product
LED Stadium Lights
Power
300W
Quantity
300 sets
Luminous Efficiency
140 lm/W
Protection
IP66 / IK09
LED Source
OSRAM SMD3030
Beam Angle
120°
CCT
5000K ±300K
Surge Protection
4KV
Dimming
Yes
Energy Saving
20%
Certification
INACAL
Warranty
2 Years
FAQ — Stadium Lighting Projects
1. Where was this stadium lighting project completed?
The project was completed for an outdoor sports facility in Iquitos, Peru.
2. What type of project was it?
It was an outdoor sports facility lighting upgrade project.
3. What LED stadium light was used?
The project used 300W LED Stadium Lights supplied by LIKELITE.
4. How many LED stadium lights were supplied?
The project quantity was 300 sets.
5. What was the reported energy-saving improvement?
The project reported a 20% energy-saving improvement.
6. What LED source was used?
The luminaires use OSRAM SMD3030 LEDs.
7. What was the luminous efficiency?
The specified luminous efficiency was 140 lm/W.
8. What was the IP protection rating?
The project luminaires were specified as IP66.
9. What was the impact protection rating?
The specified impact protection was IK09.
10. Did the stadium lights support dimming?
Yes. The supplied 300W LED Stadium Lights support dimming.
11. What lighting design services were provided?
The project engineering scope included Lighting And Circuitry Design, Onsite Metering, DIALux Evo Layout, LitePro Dlx Layout, AutoCAD Layout and AGi32 Layout support.
12. What was the warranty period?
The project lighting equipment was supplied with a 2-year warranty.
13. What certification was specified for the project?
The project specification included INACAL certification.
14. What information is required for a similar stadium lighting project?
Useful project information includes field dimensions, pole height, pole quantity, existing lighting, target illumination, input voltage, project location and required quantity.
15. Can LIKELITE supply a similar project?
Yes. LIKELITE can evaluate similar outdoor sports facility projects and provide product selection, lighting design, simulation support and bulk project supply according to project requirements.
Start Your Stadium Lighting Project
Planning an outdoor stadium or sports facility lighting upgrade?
Send LIKELITE:
Project Location + Field Dimensions + Pole Height + Pole Quantity + Existing Lighting + Required Quantity
LIKELITE can provide a project-based recommendation covering:
LED Stadium Lights → Lighting Design → DIALux Calculation → Product Supply → Installation Support