Stadium Lighting Projects/Manchester, UK Football Stadium Lighting Upgrade

300 Sets of 300W LED Stadium Lights for Football Stadiums

Project Location: Manchester, United Kingdom
Application: Football Stadiums
Project Type: Stadium Lighting Upgrade
Product: LED Stadium Lights
Power: 300W
Quantity: 300 sets
Energy-Saving Improvement: 20%
Certification: UKCA
Warranty: 3 Years
Brand: LIKELITE


Project Overview

The Manchester Football Stadium Lighting Upgrade was developed to upgrade the stadium's existing outdoor lighting system with high-efficiency LED Stadium Lights.

The project configuration included:

300 sets of 300W LED Stadium Lights

with a stated luminous efficiency of:

150 lm/W

The lighting system was configured for a UK football stadium environment using:

240V AC / 50Hz

The luminaires provide:

IP67 / IK09

outdoor protection and support dimming for different stadium operating conditions.

The project reported:

20% Energy-Saving Improvement

The supplied configuration was specified with:

UKCA Certification

and:

3-Year Warranty


Project at a Glance

Project ItemProject Information
LocationManchester, United Kingdom
ApplicationFootball Stadiums
Project TypeStadium Lighting Upgrade
ProductLED Stadium Lights
Power300W
Quantity300 sets
Luminous Efficiency150 lm/W
Input Voltage240V AC
Frequency50Hz
Beam Angle120°
CCT5000K ±300K
CRIRa 70
IP RatingIP67
IK RatingIK09
LED SourceOSRAM SMD3030
Lifespan30,000 hours
Power FactorPF >0.95
Surge Protection4KV
DimmingSupported
Working Temperature-35°C to +45°C
Product WeightApprox. 10 kg
HousingDie-casting Aluminum ADC12
LensPC Lens + Glass
Warranty3 Years
CertificationUKCA
Energy-Saving Improvement20%
BrandLIKELITE

Project Requirement

Football Stadium Lighting Upgrade

The project required an LED-based lighting upgrade suitable for an outdoor football stadium environment.

For this type of retrofit, the lighting system needs to work together with the existing:

Field + Pole Structure + Luminaire Positions + Electrical Infrastructure + Stadium Operating Requirements

The project therefore focused on a complete LED Stadium Lighting configuration rather than replacing luminaires based only on wattage.

The selected project configuration was:

300W LED Stadium Lights

with:

150 lm/W

and:

120° Beam Angle


Existing Stadium Lighting Assessment

Site and System Evaluation

A stadium lighting retrofit starts with understanding the existing installation.

The engineering assessment can include:

  • Existing luminaires
  • Existing pole positions
  • Mounting structure
  • Electrical supply
  • Circuit configuration
  • Lighting coverage
  • Operating conditions
  • Required lighting performance

LIKELITE provides:

Onsite Metering

when site measurement is required.

The purpose is to establish project information before the final LED lighting configuration is approved.


Project LED Stadium Light Configuration

300W LED Stadium Lights

The Manchester project used:

300W LED Stadium Lights

Project quantity:

300 sets

Stated luminous efficiency:

150 lm/W

LED source:

OSRAM SMD3030 LED

Beam angle:

120°

Based on the stated luminous efficiency, the nominal lumen output is approximately:

300W × 150 lm/W = 45,000 lm per luminaire

This is a nominal calculation based on the supplied product specification.

Actual field lighting performance depends on:

Mounting Height + Pole Position + Aiming Angle + Beam Distribution + Field Geometry + Installation Conditions

Therefore, lumen output should not be treated as a substitute for project-specific lighting calculations.


Optical Configuration

120° Beam Distribution

The project configuration uses:

120° Beam Angle

For football stadium applications, optical distribution must be evaluated against the actual mounting arrangement.

The final configuration should consider:

  • Pole position
  • Mounting height
  • Field dimensions
  • Luminaire spacing
  • Aiming direction
  • Beam overlap
  • Required field coverage

The objective is to achieve appropriate field coverage while controlling unnecessary light outside the playing area.


Electrical Configuration

240V AC / 50Hz

The Manchester project configuration uses:

240V AC

50Hz

PF >0.95

4KV Surge Protection

The electrical integration should be checked against the existing stadium infrastructure.

Relevant engineering considerations include:

  • Existing electrical supply
  • Circuit capacity
  • Circuit grouping
  • Protection devices
  • Cable configuration
  • Earthing
  • Surge protection
  • Dimming/control system

Final electrical installation must be verified against the actual project conditions and applicable UK requirements.


Outdoor Stadium Protection

IP67 / IK09

The project luminaires are configured for outdoor stadium conditions with:

IP67

and:

IK09

Housing:

Die-casting Aluminum ADC12

Optical construction:

PC Lens + Glass

Operating temperature:

-35°C to +45°C

Stated lifespan:

30,000 hours

The actual service life depends on operating temperature, electrical conditions, thermal management, installation environment and maintenance.


Dimming and Stadium Operation

Flexible Lighting Output

The LED Stadium Lights support:

Dimming

This allows the stadium lighting system to operate at different output levels according to the operating requirement.

Possible operating conditions include:

  • Training
  • Regular Operation
  • Competition
  • Maintenance
  • Partial-Field Operation
  • Reduced-Output Operation

The actual dimming method depends on the stadium's electrical and control architecture.


Lighting Engineering and Simulation

From Site Data to Approved Lighting Layout

The Manchester project can be supported by LIKELITE's lighting engineering services:

  • Lighting and Circuitry Design
  • Onsite Metering
  • DIALux Evo Layout
  • Litepro DLX Layout
  • AutoCAD Layout
  • AGi32 Layout
  • Project Installation

The engineering workflow is:

Site Information

Lighting Layout

Simulation

Luminaire Configuration

Electrical Design

Installation

Commissioning

The final lighting calculation should be based on the actual project geometry and approved design requirements.


Project Installation

LED Stadium Lighting Retrofit Process

01 — Site Assessment

Review the existing stadium lighting system, poles, electrical infrastructure and available project information.

02 — Onsite Metering

Collect additional site data where required.

03 — Lighting Design

Develop the project lighting layout based on the actual field and pole arrangement.

04 — Product Configuration

Configure the:

300W LED Stadium Lights

according to the approved design.

05 — Electrical Integration

Connect the new lighting system with the project electrical infrastructure.

06 — Luminaire Installation

Install and aim the luminaires according to the approved layout.

07 — Testing and Commissioning

Check electrical operation, lighting operation and dimming functions.

08 — Project Handover

Complete the project documentation and handover.


Project Result

20% Energy-Saving Improvement

The Manchester project reported:

20% Energy-Saving Improvement

The energy-saving result should be evaluated against the existing stadium lighting system.

Relevant variables include:

  • Existing luminaire wattage
  • Existing quantity
  • Operating hours
  • Proposed LED wattage
  • LED quantity
  • Dimming operation
  • Stadium usage

The 20% figure is the project result supplied for this case.

It should not be presented as a guaranteed saving for every stadium retrofit.


Technical Project Summary

The Manchester configuration combines:

300W

150 lm/W

120° Beam Angle

OSRAM SMD3030 LED

IP67 / IK09

240V AC / 50Hz

PF >0.95

4KV Surge Protection

Dimming Support

UKCA

3-Year Warranty

This configuration was applied to a:

Football Stadium Lighting Upgrade in Manchester, UK

with:

300 sets

and a reported:

20% Energy-Saving Improvement


Project Compliance

UKCA Stadium Lighting Configuration

The project specification includes:

UKCA Certification

The electrical configuration is:

240V AC / 50Hz

For UK stadium projects, final compliance should be evaluated according to the actual product configuration, electrical installation and applicable project requirements.

The final Project Documentation should ideally include the corresponding compliance documents rather than relying only on a certification statement.



Before & After Comparison


DIALux EVO Lighting Simulation Verification

Project Result

Published project result:

20% Energy-Saving Improvement

If verified Lux, uniformity or other measured data become available, they should be added together with measurement conditions.


Why This Manchester Project Matters

The Manchester Football Stadium Lighting Upgrade provides a reference for LED lighting retrofit applications in the UK sports sector.

The project combines:

300 Sets

300W LED Stadium Lights

150 lm/W

240V AC / 50Hz

UKCA

3-Year Warranty

with a reported:

20% Energy-Saving Improvement

For EPC contractors and engineering companies, the project provides a practical reference point for evaluating LED Stadium Lighting Retrofit requirements.


 

FAQ — Manchester Football Stadium Lighting Project

1. Where is the LIKELITE Stadium Lighting Project located?

The project is located in Manchester, United Kingdom.

2. What type of stadium was upgraded?

The project was a Football Stadium Lighting Upgrade.

3. How many LED Stadium Lights were used?

The project quantity was 300 sets.

4. What wattage was used?

The project used 300W LED Stadium Lights.

5. What was the stated luminous efficiency?

The specified luminous efficiency was 150 lm/W.

6. What is the nominal lumen output of each 300W luminaire?

Based on the supplied efficiency specification:

300W × 150 lm/W = approximately 45,000 lm

This is a nominal calculation and is not a substitute for field lighting calculations.

7. What electrical input was used?

The project configuration uses 240V AC / 50Hz.

8. What certification was specified?

The project specification includes UKCA.

9. What is the outdoor protection rating?

The configuration uses IP67 / IK09.

10. Do the stadium lights support dimming?

Yes. The project configuration supports dimming.

11. What LED source was used?

The project uses OSRAM SMD3030 LED.

12. What is the warranty period?

The project specification provides a 3-year warranty.

13. What energy-saving result was reported?

The project reported a 20% Energy-Saving Improvement.

14. What engineering services can LIKELITE provide?

Services include:

Lighting and Circuitry Design + Onsite Metering + DIALux Evo + Litepro DLX + AutoCAD + AGi32 + Project Installation

15. Can another stadium directly copy the Manchester configuration?

Not automatically.

A new stadium should be evaluated based on:

Field Dimensions + Pole Layout + Pole Height + Existing Lighting + Electrical Infrastructure + Required Lighting Performance

before determining the final LED Stadium Lighting configuration.


Request a Similar Stadium Lighting Project

For a new football stadium lighting retrofit, send LIKELITE:

Project Location + Field Dimensions + Pole Layout + Pole Height + Existing Luminaire Specifications + Existing Quantity + Required Lighting Level

LIKELITE can evaluate the project and develop the appropriate LED Stadium Lighting configuration, lighting layout and engineering documentation.

LIKELITE — LED Stadium Lighting Projects for Football Stadiums, EPC Contractors, Engineering Companies and Project Buyers.