Stadium Lighting Projects/Ottawa, Canada Football Stadium Lighting Upgrade

500 Sets of 150W LED Stadium Lights for Football Stadiums

Project Location: Ottawa, Canada
Application: Football Stadiums
Project Type: Stadium Lighting Upgrade
Product: LED Stadium Lights
Power: 150W
Quantity: 500 sets
Energy-Saving Improvement: 20%
Certification: CSA
Warranty: 3 Years
Brand: LIKELITE


Project Overview

The Ottawa football stadium lighting upgrade was developed to replace or upgrade the existing outdoor stadium lighting system with high-efficiency LED Stadium Lights.

The project used:

500 sets × 150W LED Stadium Lights

with a stated luminous efficiency of:

130 lm/W

The lighting configuration was designed for outdoor football stadium applications, with emphasis on high-output illumination, wide-area coverage, outdoor protection, electrical compatibility and dimming capability.

The project reported an approximately:

20% Energy-Saving Improvement

The project configuration was supplied by LIKELITE with CSA certification and a 3-year warranty.


Project at a Glance

Project ItemProject Information
LocationOttawa, Canada
ApplicationFootball Stadiums
Project TypeStadium Lighting Upgrade
ProductLED Stadium Lights
Power150W
Quantity500 sets
Luminous Efficiency130 lm/W
Input Voltage110-120V AC
Frequency60Hz
Beam Angle120°
CCT5000K ±400K
CRIRa 70
IP RatingIP67
IK RatingIK09
LED SourceOSRAM SMD3030
Lifespan30,000 hours
Power FactorPF >0.95
Surge Protection4KV
DimmingSupported
Working Temperature-35°C to +45°C
Product WeightApprox. 4.5 kg
Warranty3 Years
CertificationCSA
Energy-Saving Improvement20%
ManufacturerLIKELITE

Project Background

Football Stadium Lighting Upgrade

Outdoor football stadium lighting operates over large playing areas and typically requires multiple luminaires working together to provide the required field coverage.

For an existing stadium, the lighting upgrade must consider the relationship between:

Existing Lighting System → Pole Arrangement → Luminaire Configuration → Electrical System → Lighting Distribution → Operating Requirements

The Ottawa project was configured around a high-efficiency LED stadium lighting system using 150W luminaires.

The project quantity was:

500 sets

The stated energy-saving improvement was:

20%


Project LED Stadium Light Configuration

150W LED Stadium Lights

The project used LIKELITE LED Stadium Lights with a rated power of:

150W

and luminous efficiency of:

130 lm/W

The LED source is:

OSRAM SMD3030 LED

The optical configuration uses:

120° Beam Angle

This configuration provides a wide beam distribution for large outdoor sports applications.

Actual lighting performance depends on the field dimensions, mounting position, installation height, aiming angle and final lighting layout.


Electrical Configuration

110-120V AC / 60Hz

The Ottawa project configuration uses:

Input Voltage: 110-120V AC

Frequency: 60Hz

Power Factor: PF >0.95

Surge Protection: 4KV

This configuration is relevant to North American electrical environments.

Final electrical connection, circuit grouping and installation must be verified against the actual stadium electrical infrastructure and applicable local requirements.


Outdoor Protection

IP67 / IK09

The LED Stadium Lights are designed for outdoor stadium applications.

The project configuration uses:

IP67 / IK09

The luminaire construction consists of:

Die-casting Aluminum ADC12 + PC Lens + Glass

The specified operating temperature range is:

-35°C to +45°C

The stated product lifespan is:

30,000 hours

Actual service life depends on operating temperature, electrical conditions, installation environment and maintenance.


Dimming Capability

Stadium Lighting Control

The project LED Stadium Lights support dimming.

This provides the possibility of adjusting the lighting output according to the stadium operating requirements, subject to the installed control system.

Typical operating modes can include:

  • Training

  • Regular Operation

  • Competition

  • Maintenance

  • Partial-Field Operation

The actual dimming method and control architecture should be confirmed according to the project electrical system.


Project Lighting Engineering

Lighting Design and Technical Support

The Ottawa project included access to LIKELITE lighting engineering services covering:

  • Lighting and Circuitry Design

  • Onsite Metering

  • DIALux Evo Layout

  • Litepro DLX Layout

  • AutoCAD Layout

  • AGi32 Layout

  • Project Installation

These services support the project from existing-system assessment through lighting design and installation.

For a complete project record, actual project documents can include:

Lighting Layout + DIALux Calculation + AGi32 Calculation + Onsite Metering + Electrical Drawings + Installation Records + Commissioning Documentation

Only verified project measurements should be published as final performance data.


Project Installation

LED Stadium Lighting Retrofit Process

The Ottawa project can be documented through the following project delivery sequence:

01 — Existing System Assessment

Review the existing stadium lighting system, luminaires, poles and electrical infrastructure.

02 — Onsite Measurement

Collect site information required for the lighting layout and replacement configuration.

03 — Lighting Layout

Develop the project-specific lighting layout using appropriate lighting design software.

04 — LED Configuration

Configure the 150W LED Stadium Lights according to the project design requirements.

05 — Electrical Installation

Complete circuit connection and electrical integration.

06 — Luminaire Installation

Install and aim the LED Stadium Lights according to the approved lighting layout.

07 — Testing and Commissioning

Check electrical operation, lighting operation and control functions.

08 — Project Handover

Complete the project documentation and handover process.


Project Result

20% Energy-Saving Improvement

The Ottawa football stadium lighting upgrade reported:

20% Energy-Saving Improvement

The energy-saving result should be evaluated by comparing the existing lighting system with the upgraded LED system.

Relevant factors include:

  • Existing luminaire wattage

  • Existing quantity

  • Existing operating hours

  • Proposed LED wattage

  • LED quantity

  • Dimming operation

  • Actual stadium usage

The 20% improvement is the project result provided for this case.

No additional energy-saving percentage is assumed.


Technical Performance Summary

High-Efficiency LED Stadium Lighting

The project configuration combines:

150W Power
+
130 lm/W Luminous Efficiency
+
120° Beam Angle
+
OSRAM SMD3030 LED
+
IP67 / IK09
+
110-120V AC / 60Hz
+
PF >0.95
+
4KV Surge Protection
+
Dimming Support

This configuration was developed for outdoor football stadium lighting applications.


Project Compliance

CSA-Certified Stadium Lighting Configuration

The Ottawa project configuration includes:

CSA Certification

The product configuration is also specified for:

110-120V AC / 60Hz

For Canadian projects, final product compliance, electrical installation and project requirements should be confirmed according to the specific application and applicable Canadian standards.

The project certification should be supported by the corresponding compliance documentation in the final project file.


Before & After Comparison


DIALux EVO Lighting Simulation Verification

Project Result

Primary published project result:

20% Energy-Saving Improvement

If actual measured Lux, uniformity or other performance data become available, those figures should be added to the project page with the corresponding measurement conditions.


Why This Ottawa Project Matters

The Ottawa project demonstrates LIKELITE's application of LED stadium lighting in a Canadian football stadium environment.

The project combines:

500 Sets

150W LED Stadium Lights

130 lm/W

110-120V AC

60Hz

CSA

3-Year Warranty

with a reported:

20% Energy-Saving Improvement

The project therefore provides a practical reference for football stadium operators, EPC contractors, engineering companies and project buyers evaluating LED stadium lighting upgrades in Canada and other North American markets.


FAQ — Ottawa Football Stadium Lighting Project

1. Where is the LIKELITE stadium lighting project located?

The project is located in Ottawa, Canada.

2. What type of stadium was upgraded?

The project was a Football Stadium lighting upgrade.

3. How many LED Stadium Lights were used?

The project used 500 sets.

4. What wattage were the LED Stadium Lights?

The project used 150W LED Stadium Lights.

5. What was the luminous efficiency?

The stated luminous efficiency was 130 lm/W.

6. What beam angle was used?

The project configuration uses a 120° beam angle.

7. What electrical input was specified?

The project configuration uses 110-120V AC / 60Hz.

8. What certification was provided?

The stated certification is CSA.

9. What is the protection rating?

The project configuration is rated IP67 / IK09.

10. Do the LED Stadium Lights support dimming?

Yes. The project configuration supports dimming.

11. What LED source was used?

The project configuration uses OSRAM SMD3030 LED.

12. What is the warranty period?

The stated warranty is 3 years.

13. What energy-saving result was achieved?

The project reported an approximately 20% Energy-Saving Improvement.

14. What engineering services were included?

The service scope includes Lighting and Circuitry Design, Onsite Metering, DIALux Evo Layout, Litepro DLX Layout, AutoCAD Layout, AGi32 Layout and Project Installation.

15. Can the Ottawa 150W configuration be directly applied to another football stadium?

Not necessarily. Each stadium should be evaluated according to its field dimensions, pole arrangement, mounting height, existing electrical system and required lighting performance.


Request a Similar Stadium Lighting Project

For a football stadium lighting upgrade, send LIKELITE:

Project Location + Field Dimensions + Pole Layout + Pole Height + Existing Luminaire Specifications + Existing Quantity + Required Lighting Level

LIKELITE can evaluate the project requirements and develop the appropriate LED Stadium Lighting configuration.

LIKELITE — Professional LED Stadium Lighting Projects for Football Stadiums, EPC Contractors, Engineering Companies and Project Buyers.