Stadium Lighting Projects/Porto, Portugal Outdoor Sports Lighting Upgrade

Project Location: Porto, Portugal
Application: Outdoor Sports Facility
Project Type: Sports Lighting Upgrade
Product: LED Stadium Lights
Project Quantity: 600 sets
LED Power: 200W
Reported Energy-Saving Improvement: 20%
Warranty: 2 Years
Brand: LIKELITE
Origin: Guangdong, China

Project Overview

This project involved an outdoor sports lighting upgrade in Porto, Portugal.

The project specification included 600 sets of 200W LED Stadium Lights for outdoor sports lighting applications.

The lighting configuration was developed around high-output illumination, controlled light distribution, fixture durability and adjustable lighting operation.

The specified LED Stadium Lights included dimming support, allowing the lighting output to be adjusted according to applicable operating requirements.

The project reported a 20% energy-saving improvement following the lighting upgrade.

This 20% figure is a project-specific reported result. Actual energy savings can vary according to the existing lighting system, operating hours, replacement wattage, lighting levels and control strategy.

Project Scope

The project covered LED stadium lighting supply together with the specified engineering and installation services.

The service scope included:

  • Lighting and Circuitry Design

  • Onsite Metering

  • DIALux Evo Layout

  • LitePro DLX Layout

  • AutoCAD Layout

  • AGI32 Layout

  • Project Installation

The engineering services were coordinated with the sports facility layout and the selected LED Stadium Light configuration.

Project Product

200W LED Stadium Lights

The project used a 200W LED Stadium Light configuration.

ItemProject Specification
ProductLED Stadium Lights
Power200W
Quantity600 sets
Input Voltage220V / 380V AC
LED SourceOSRAM SMD2835 LED
Luminous Efficiency150 lm/W
Beam Angle120°
IP RatingIP66
Impact RatingIK09
CCT5000K ±300K
CRIRa70
DimmingSupported
PF0.95
Surge Protection4KV
Lifespan30,000 hours
Frequency50Hz
MaterialDie-Casting Aluminum ADC12
LensPC Lens + Glass
Working Temperature-35°C to 45°C
Product Weight9.55 kg
Warranty2 Years
CertificationCE-LVD / EMC / ErP
BrandLIKELITE
OriginGuangdong, China

Lighting Performance Configuration

The selected product configuration was based on the requirements of an outdoor sports lighting application.

The main performance specifications included:

150 lm/W luminous efficiency
Provides high-output LED lighting from a 200W fixture.

120° beam angle
Provides broad light distribution for applicable outdoor sports lighting layouts.

IP66 protection
Specified for protection against dust and water exposure in the outdoor application.

IK09 impact protection
Provides a defined mechanical impact protection level for the specified fixture.

PF 0.95
The specified power factor for the project configuration.

4KV surge protection
Provides specified surge protection for the LED lighting equipment.

Dimming Capability

The project configuration supported dimming.

For sports facilities, lighting requirements can vary between different operating conditions.

The lighting system can therefore be configured around different usage periods, such as:

  • Training

  • Normal Facility Operation

  • Sports Events

  • Maintenance

The actual dimming settings should be determined according to the facility's lighting requirements and control system.

Project Engineering Services

The project service scope included several engineering activities.

Lighting and Circuitry Design

Lighting positions and electrical circuitry were coordinated with the outdoor sports facility requirements.

Onsite Metering

Site measurements provided the information required for lighting layout and project engineering.

DIALux Evo Layout

DIALux Evo was included in the specified photometric design workflow.

LitePro DLX Layout

LitePro DLX layout support was included for applicable project requirements.

AutoCAD Layout

AutoCAD was used as part of the project layout and engineering coordination process.

AGI32 Layout

AGI32 layout support was included for applicable lighting calculation requirements.

Project Installation

The service scope included project installation.

Project Execution

The project followed a defined engineering and supply process:

Site Assessment

Onsite Metering

Lighting & Circuitry Design

Photometric Layout

LED Stadium Light Configuration

Dimming Configuration

Production & Supply

Project Installation

The purpose of the engineering process was to coordinate the LED lighting equipment with the actual sports facility rather than treating the project as a standard product-only order.

Project Energy Result

The reported energy-saving improvement was:

20%

The result is specific to this Porto outdoor sports lighting application.

Energy performance can be influenced by:

  • Existing fixture technology

  • Existing fixture wattage

  • LED replacement wattage

  • Daily operating hours

  • Lighting operating levels

  • Dimming settings

  • Facility usage

  • Control strategy

The 20% result should therefore be presented as a project-specific reported result, rather than a guaranteed performance figure for all stadium lighting projects.

Project Scale

600 Sets of 200W LED Stadium Lights

The project quantity was 600 sets.

For a project of this scale, consistent product specifications, technical documentation, photometric files, certification documents, packaging and delivery coordination are important procurement considerations.

The defined 200W configuration provided a standardized product specification for the project supply.

Product Features

The specified product included:

High Bright

The 150 lm/W luminous efficiency supports high-output LED lighting applications.

Lightweight

The specified product weight was 9.55 kg, supporting practical handling during project installation.

Plus Size

The Plus Size configuration was specified for high-output outdoor lighting applications requiring broad-area illumination.

Outdoor Protection

The product specification included IP66 / IK09 protection.

Dimming Support

Dimming capability allows lighting output to be adjusted according to applicable operating requirements.

Certification and Compliance

The project specification included:

  • CE-LVD

  • EMC

  • ErP

These documents can be included within the technical documentation package according to project requirements.

Packaging and Product Information

The specified product information included:

  • Product Weight: 9.55 kg

  • Material: Die-Casting Aluminum ADC12

  • Lens: PC Lens + Glass

  • Working Temperature: -35°C to 45°C

  • Frequency: 50Hz

Packaging and shipment information can be coordinated according to project procurement requirements.

Project Documentation

The project documentation package can include:

  • Product Datasheet

  • Technical Specifications

  • CE-LVD Documentation

  • EMC Documentation

  • ErP Documentation

  • Photometric Data

  • DIALux Layout

  • LitePro DLX Layout

  • AutoCAD Layout

  • AGI32 Layout

  • Installation Information

  • Warranty Documentation

Additional project documents can be displayed when available.

Before & After Comparison



DIALux EVO Lighting Simulation Verification

Project Buyer Relevance

This project is relevant to buyers involved in:

  • Stadium construction

  • Sports facility renovation

  • Outdoor sports lighting upgrades

  • Football field lighting

  • Training facility lighting

  • Engineering projects

  • Electrical contracting

  • Bulk LED lighting procurement

Typical project stakeholders include:

  • Sports Facility EPC Contractors

  • Stadium Contractors

  • Electrical Contractors

  • Engineering Companies

  • Sports Facility Owners

  • Lighting Distributors

  • Lighting Importers

  • Bulk Project Buyers

Why This Project Is Relevant to Stadium Lighting Procurement

The Porto reference project provides a defined combination of:

600 sets
Large-volume project supply.

200W LED Stadium Lights
Defined product configuration.

150 lm/W
Specified luminous efficiency.

IP66 / IK09
Outdoor protection and impact protection.

Dimming Support
Adjustable lighting operation.

OSRAM SMD2835 LED
Specified LED source.

CE-LVD / EMC / ErP
Specified certification and compliance documentation.

4KV Surge Protection
Specified electrical protection.

20% Reported Energy-Saving Improvement
Project-specific reported result.

Engineering Services
Lighting design, onsite metering, DIALux, LitePro DLX, AutoCAD, AGI32 and project installation.

Stadium Lighting Solutions vs. Stadium Lighting Projects

This page records the Porto, Portugal outdoor sports lighting project.

The separate Stadium Lighting Solutions page explains how LIKELITE approaches stadium and outdoor sports lighting requirements.

The distinction is intentional:

PageMain Content
Stadium Lighting SolutionsCapability, methodology, design and solution structure
Stadium Lighting ProjectsProject location, quantity, product, execution, result and evidence

Solutions = How LIKELITE solves the lighting requirement

Projects = What LIKELITE supplied and delivered

The detailed Porto project facts belong on this Projects page, while general stadium lighting design methodology remains on the Solutions page.

FAQ — Porto Stadium Lighting Project

1. Where was this stadium lighting project located?

The reference project was located in Porto, Portugal.

2. What type of facility was involved?

The project was an outdoor sports lighting upgrade.

3. What LED lighting product was supplied?

The project used 200W LED Stadium Lights.

4. How many LED Stadium Lights were supplied?

The specified quantity was 600 sets.

5. What was the luminous efficiency?

The specified luminous efficiency was 150 lm/W.

6. What LED source was used?

The project specification used OSRAM SMD2835 LED.

7. What were the IP and IK ratings?

The specified protection ratings were IP66 and IK09.

8. Do the LED Stadium Lights support dimming?

Yes. The specified 200W LED Stadium Lights support dimming.

9. What was the reported energy-saving improvement?

The reported energy-saving improvement was 20%. This is a project-specific result.

10. What certifications were specified?

The project specification included CE-LVD, EMC and ErP.

11. What was the warranty period?

The specified warranty was 2 years.

12. What was the operating temperature?

The specified working temperature was -35°C to 45°C.

13. What surge protection was specified?

The project configuration specified 4KV surge protection.

14. Did LIKELITE provide lighting design and photometric layouts?

Yes. The service scope included Lighting and Circuitry Design, Onsite Metering, DIALux Evo, LitePro DLX, AutoCAD and AGI32 layouts.

15. Can LIKELITE provide project installation?

Yes. Project Installation was included in the specified service scope.

Request a Similar Stadium Lighting Project

If you are planning a stadium, sports field, training facility or outdoor sports lighting upgrade, send LIKELITE:

Project Location + Field Dimensions + Mounting Height + Existing Lighting Information + Required Quantity

LIKELITE can coordinate the appropriate:

LED Stadium Lights + Photometric Layout + Circuitry Design + Dimming Configuration + Project Supply

LIKELITE — LED Stadium Lighting Supply for International Sports Projects