600 Sets of 100W LED Stadium Lights for Outdoor Baseball Fields
Project Location: Santiago, Chile
Application: Baseball Fields
Project Type: Stadium Lighting Upgrade
Product: LED Stadium Lights
Power: 100W
Quantity: 600 sets
Energy-Saving Improvement: 20%
Certification: SEC
Warranty: 2 Years
Brand: LIKELITE
Project Overview
A baseball field lighting upgrade requires more than replacing conventional luminaires with LED products.
The lighting system must be configured around the actual playing area, existing lighting infrastructure, electrical conditions and operational requirements.
For this Santiago, Chile project, LIKELITE supplied 600 sets of 100W LED Stadium Lights for a baseball field lighting upgrade.
The project configuration was developed for outdoor sports lighting, with emphasis on high-output illumination, broad beam coverage, outdoor protection, electrical efficiency and controllable operation.
The completed project reported an approximately 20% energy-saving improvement compared with the previous lighting configuration.
Project at a Glance
| Project Item | Project Information |
|---|---|
| Location | Santiago, Chile |
| Application | Baseball Fields |
| Project Type | Stadium Lighting Upgrade |
| LED Stadium Light | 100W |
| Quantity | 600 sets |
| Luminous Efficiency | 110 lm/W |
| Input Voltage | 220V AC |
| Beam Angle | 110° |
| Color Temperature | 5000K ±300K |
| CRI | Ra 70 |
| Protection | IP67 / IK09 |
| LED Source | OSRAM SMD2835 |
| Power Factor | PF >0.95 |
| Surge Protection | 4KV |
| Dimming | Supported |
| Operating Temperature | -35°C to +45°C |
| Frequency | 50Hz |
| Product Weight | Approx. 4 kg |
| Warranty | 2 Years |
| Certification | SEC |
| Energy-Saving Improvement | 20% |
| Manufacturer | LIKELITE |
Project Requirements
Existing Baseball Field Lighting Upgrade
The project required an upgrade of the existing outdoor baseball field lighting system.
For a sports lighting retrofit, the replacement system must be evaluated according to the actual field application rather than by luminaire wattage alone.
The project required a solution combining:
LED technology
High luminous efficiency
Outdoor protection
Wide-area beam coverage
Stable 220V AC operation
Dimming capability
High power factor
Surge protection
Long-term outdoor operation
Project-specific lighting design support
LIKELITE configured the project around these requirements.
LED Stadium Lighting Configuration
100W LED Stadium Lights
The project used 600 sets of 100W LED Stadium Lights.
With a stated luminous efficiency of 110 lm/W, each 100W luminaire provides a nominal LED output configuration of approximately 11,000 lumens before project-specific optical and installation considerations.
The luminaire uses:
OSRAM SMD2835 LED
and a 110° beam angle for broad outdoor light distribution.
The product configuration was selected for the project application rather than presented as a universal specification for every baseball field.
Outdoor Protection
IP67 / IK09 Stadium Lighting
Baseball field lighting equipment is exposed to outdoor environmental conditions throughout its operating life.
The project luminaire configuration uses:
IP67 / IK09
The housing is based on:
Die-casting Aluminum ADC12 + PC Lens + Glass
with a stated operating temperature range of:
-35°C to +45°C
This configuration provides a robust outdoor luminaire structure for sports-field applications.
Electrical Configuration
220V AC / PF >0.95 / 4KV Surge Protection
The project lighting configuration uses:
Input Voltage: 220V AC
Frequency: 50Hz
Power Factor: PF >0.95
Surge Protection: 4KV
The electrical configuration was specified for the project application and should be integrated with the actual site electrical system during installation.
Dimming Capability
Adjustable Stadium Lighting Operation
The project LED Stadium Lights support dimming.
This provides the possibility of adapting lighting output to different operating conditions where the project control system supports the required dimming method.
Typical operating conditions may include:
Training
Regular operation
Competition
Maintenance
Partial-field operation
The actual control strategy depends on the project's electrical and lighting-control architecture.
Project Lighting Design and Engineering Support
Lighting Design Documentation
The project was supported by LIKELITE's lighting engineering services, including:
Lighting and Circuitry Design
Onsite Metering
DIALux Evo Layout
Litepro DLX Layout
AutoCAD Layout
AGi32 Layout
Project Installation Support
These services support the project from lighting assessment and design through installation.
For the final project record, actual lighting simulation files and measured field data should be retained as project documentation.
Project Installation
From Product Supply to Field Installation
The stadium lighting upgrade requires coordinated work between product supply, lighting design, electrical installation and final commissioning.
The project delivery sequence can be documented as:
Existing System Assessment
↓
Onsite Measurement
↓
Lighting Layout
↓
LED Stadium Light Configuration
↓
Electrical & Circuitry Planning
↓
Installation
↓
Testing & Commissioning
↓
Project Handover
For the Santiago project, LIKELITE provided project installation support as part of the lighting solution service.
Project Result
20% Energy-Saving Improvement
The Santiago baseball field lighting upgrade achieved a reported:
20% Energy-Saving Improvement
The energy-saving result should be evaluated against the previous lighting system based on:
Existing luminaire power
Existing quantity
LED replacement power
Operating hours
Dimming operation
Actual field usage
The stated 20% improvement is the project result supplied for this case.
No additional savings percentage is assumed beyond the project data provided.
Project Technical Summary
Product
LIKELITE LED Stadium Lights
Configuration
100W / 600 sets
Optical Performance
110 lm/W / 110° Beam Angle
Light Source
OSRAM SMD2835 LED
Electrical
220V AC / 50Hz / PF >0.95
Protection
IP67 / IK09 / 4KV Surge Protection
CCT
5000K ±300K
CRI
Ra 70
Operating Temperature
-35°C to +45°C
Dimming
Supported
Warranty
2 Years
Certification
SEC
Project Result
20% Energy-Saving Improvement
Before & After Comparison



DIALux EVO Lighting Simulation Verification

Why This Project Matters
The Santiago project demonstrates the application of LED stadium lighting in a real outdoor baseball field environment.
The project combines:
600 Sets + 100W LED Stadium Lights + 110 lm/W + IP67/IK09 + 220V AC + Dimming + SEC Certification + 2-Year Warranty
with a reported:
20% Energy-Saving Improvement
This makes the project a useful reference for baseball fields, sports facilities and outdoor stadium lighting retrofit applications.
Project FAQ
1. Where is this stadium lighting project located?
The project is located in Santiago, Chile.
2. What type of sports facility was upgraded?
The project was a Baseball Field lighting upgrade.
3. How many LED Stadium Lights were supplied?
The project used 600 sets.
4. What wattage were the LED Stadium Lights?
The project used 100W LED Stadium Lights.
5. What was the luminous efficiency?
The stated luminous efficiency was 110 lm/W.
6. What beam angle was used?
The project configuration used a 110° beam angle.
7. What input voltage was used?
The specified input voltage was 220V AC, with a frequency of 50Hz.
8. What protection rating did the stadium lights have?
The project configuration was rated IP67 / IK09.
9. Did the stadium lights support dimming?
Yes. The project LED Stadium Lights support dimming.
10. What LED source was used?
The project configuration used OSRAM SMD2835 LED.
11. What certification was provided?
The stated certification for the project configuration was SEC.
12. What was the warranty period?
The stated warranty was 2 years.
13. What energy-saving result was achieved?
The project reported an approximately 20% energy-saving improvement.
14. Did LIKELITE provide lighting design support?
Yes. The project service scope included Lighting and Circuitry Design, Onsite Metering, DIALux Evo, Litepro DLX, AutoCAD and AGi32 layout support, together with project installation support.
15. Can this project configuration be directly copied to another baseball field?
Not necessarily. Stadium lighting should be designed according to the actual field dimensions, pole arrangement, mounting height, target lighting requirements and electrical conditions. The Santiago configuration should be treated as a project reference rather than a universal specification.
Request a Similar Stadium Lighting Project
If you are planning a baseball field or outdoor stadium lighting upgrade, send LIKELITE:
Project Location + Field Dimensions + Pole Layout + Pole Height + Existing Luminaire Specifications + Existing Quantity + Target Lighting Requirements
LIKELITE can evaluate the project requirements and develop the appropriate LED Stadium Lighting configuration.
LIKELITE — LED Stadium Lighting Projects for EPC Contractors, Engineering Companies, Sports Facilities and Project Buyers.






