Stadium Lighting Projects/Santiago, Chile Baseball Field Lighting Upgrade

600 Sets of 100W LED Stadium Lights for Outdoor Baseball Fields

Project Location: Santiago, Chile
Application: Baseball Fields
Project Type: Stadium Lighting Upgrade
Product: LED Stadium Lights
Power: 100W
Quantity: 600 sets
Energy-Saving Improvement: 20%
Certification: SEC
Warranty: 2 Years
Brand: LIKELITE


Project Overview

A baseball field lighting upgrade requires more than replacing conventional luminaires with LED products.

The lighting system must be configured around the actual playing area, existing lighting infrastructure, electrical conditions and operational requirements.

For this Santiago, Chile project, LIKELITE supplied 600 sets of 100W LED Stadium Lights for a baseball field lighting upgrade.

The project configuration was developed for outdoor sports lighting, with emphasis on high-output illumination, broad beam coverage, outdoor protection, electrical efficiency and controllable operation.

The completed project reported an approximately 20% energy-saving improvement compared with the previous lighting configuration.


Project at a Glance

Project ItemProject Information
LocationSantiago, Chile
ApplicationBaseball Fields
Project TypeStadium Lighting Upgrade
LED Stadium Light100W
Quantity600 sets
Luminous Efficiency110 lm/W
Input Voltage220V AC
Beam Angle110°
Color Temperature5000K ±300K
CRIRa 70
ProtectionIP67 / IK09
LED SourceOSRAM SMD2835
Power FactorPF >0.95
Surge Protection4KV
DimmingSupported
Operating Temperature-35°C to +45°C
Frequency50Hz
Product WeightApprox. 4 kg
Warranty2 Years
CertificationSEC
Energy-Saving Improvement20%
ManufacturerLIKELITE

Project Requirements

Existing Baseball Field Lighting Upgrade

The project required an upgrade of the existing outdoor baseball field lighting system.

For a sports lighting retrofit, the replacement system must be evaluated according to the actual field application rather than by luminaire wattage alone.

The project required a solution combining:

  • LED technology

  • High luminous efficiency

  • Outdoor protection

  • Wide-area beam coverage

  • Stable 220V AC operation

  • Dimming capability

  • High power factor

  • Surge protection

  • Long-term outdoor operation

  • Project-specific lighting design support

LIKELITE configured the project around these requirements.


LED Stadium Lighting Configuration

100W LED Stadium Lights

The project used 600 sets of 100W LED Stadium Lights.

With a stated luminous efficiency of 110 lm/W, each 100W luminaire provides a nominal LED output configuration of approximately 11,000 lumens before project-specific optical and installation considerations.

The luminaire uses:

OSRAM SMD2835 LED

and a 110° beam angle for broad outdoor light distribution.

The product configuration was selected for the project application rather than presented as a universal specification for every baseball field.


Outdoor Protection

IP67 / IK09 Stadium Lighting

Baseball field lighting equipment is exposed to outdoor environmental conditions throughout its operating life.

The project luminaire configuration uses:

IP67 / IK09

The housing is based on:

Die-casting Aluminum ADC12 + PC Lens + Glass

with a stated operating temperature range of:

-35°C to +45°C

This configuration provides a robust outdoor luminaire structure for sports-field applications.


Electrical Configuration

220V AC / PF >0.95 / 4KV Surge Protection

The project lighting configuration uses:

Input Voltage: 220V AC
Frequency: 50Hz
Power Factor: PF >0.95
Surge Protection: 4KV

The electrical configuration was specified for the project application and should be integrated with the actual site electrical system during installation.


Dimming Capability

Adjustable Stadium Lighting Operation

The project LED Stadium Lights support dimming.

This provides the possibility of adapting lighting output to different operating conditions where the project control system supports the required dimming method.

Typical operating conditions may include:

  • Training

  • Regular operation

  • Competition

  • Maintenance

  • Partial-field operation

The actual control strategy depends on the project's electrical and lighting-control architecture.


Project Lighting Design and Engineering Support

Lighting Design Documentation

The project was supported by LIKELITE's lighting engineering services, including:

  • Lighting and Circuitry Design

  • Onsite Metering

  • DIALux Evo Layout

  • Litepro DLX Layout

  • AutoCAD Layout

  • AGi32 Layout

  • Project Installation Support

These services support the project from lighting assessment and design through installation.

For the final project record, actual lighting simulation files and measured field data should be retained as project documentation.


Project Installation

From Product Supply to Field Installation

The stadium lighting upgrade requires coordinated work between product supply, lighting design, electrical installation and final commissioning.

The project delivery sequence can be documented as:

Existing System Assessment

Onsite Measurement

Lighting Layout

LED Stadium Light Configuration

Electrical & Circuitry Planning

Installation

Testing & Commissioning

Project Handover

For the Santiago project, LIKELITE provided project installation support as part of the lighting solution service.


Project Result

20% Energy-Saving Improvement

The Santiago baseball field lighting upgrade achieved a reported:

20% Energy-Saving Improvement

The energy-saving result should be evaluated against the previous lighting system based on:

  • Existing luminaire power

  • Existing quantity

  • LED replacement power

  • Operating hours

  • Dimming operation

  • Actual field usage

The stated 20% improvement is the project result supplied for this case.

No additional savings percentage is assumed beyond the project data provided.


Project Technical Summary

Product

LIKELITE LED Stadium Lights

Configuration

100W / 600 sets

Optical Performance

110 lm/W / 110° Beam Angle

Light Source

OSRAM SMD2835 LED

Electrical

220V AC / 50Hz / PF >0.95

Protection

IP67 / IK09 / 4KV Surge Protection

CCT

5000K ±300K

CRI

Ra 70

Operating Temperature

-35°C to +45°C

Dimming

Supported

Warranty

2 Years

Certification

SEC

Project Result

20% Energy-Saving Improvement


Before & After Comparison


DIALux EVO Lighting Simulation Verification

Why This Project Matters

The Santiago project demonstrates the application of LED stadium lighting in a real outdoor baseball field environment.

The project combines:

600 Sets + 100W LED Stadium Lights + 110 lm/W + IP67/IK09 + 220V AC + Dimming + SEC Certification + 2-Year Warranty

with a reported:

20% Energy-Saving Improvement

This makes the project a useful reference for baseball fields, sports facilities and outdoor stadium lighting retrofit applications.


Project FAQ

1. Where is this stadium lighting project located?

The project is located in Santiago, Chile.

2. What type of sports facility was upgraded?

The project was a Baseball Field lighting upgrade.

3. How many LED Stadium Lights were supplied?

The project used 600 sets.

4. What wattage were the LED Stadium Lights?

The project used 100W LED Stadium Lights.

5. What was the luminous efficiency?

The stated luminous efficiency was 110 lm/W.

6. What beam angle was used?

The project configuration used a 110° beam angle.

7. What input voltage was used?

The specified input voltage was 220V AC, with a frequency of 50Hz.

8. What protection rating did the stadium lights have?

The project configuration was rated IP67 / IK09.

9. Did the stadium lights support dimming?

Yes. The project LED Stadium Lights support dimming.

10. What LED source was used?

The project configuration used OSRAM SMD2835 LED.

11. What certification was provided?

The stated certification for the project configuration was SEC.

12. What was the warranty period?

The stated warranty was 2 years.

13. What energy-saving result was achieved?

The project reported an approximately 20% energy-saving improvement.

14. Did LIKELITE provide lighting design support?

Yes. The project service scope included Lighting and Circuitry Design, Onsite Metering, DIALux Evo, Litepro DLX, AutoCAD and AGi32 layout support, together with project installation support.

15. Can this project configuration be directly copied to another baseball field?

Not necessarily. Stadium lighting should be designed according to the actual field dimensions, pole arrangement, mounting height, target lighting requirements and electrical conditions. The Santiago configuration should be treated as a project reference rather than a universal specification.


Request a Similar Stadium Lighting Project

If you are planning a baseball field or outdoor stadium lighting upgrade, send LIKELITE:

Project Location + Field Dimensions + Pole Layout + Pole Height + Existing Luminaire Specifications + Existing Quantity + Target Lighting Requirements

LIKELITE can evaluate the project requirements and develop the appropriate LED Stadium Lighting configuration.

LIKELITE — LED Stadium Lighting Projects for EPC Contractors, Engineering Companies, Sports Facilities and Project Buyers.